两种半硬质瓣环成形装置对二尖瓣环动力学可持续性的比较
结果显示Physio II环在收缩期鞍形恢复上更优,而Memo 3D环显示更大的前后径变化和瓣环高度折叠动力学,且这些差异在术后1年仍持续存在,两组二尖瓣功能无显著差异。
要点
- Physio II环收缩期鞍形恢复更优,鞍形高度与连合宽度比值更大。
- Memo 3D环前后径变化和瓣环高度折叠动力学更显著。
- 两种装置的二尖瓣功能无显著差异,动力学差异可持续1年。
核心结论
- Physio II环在收缩期三维鞍形恢复上优于Memo 3D环,而Memo 3D环显示更大的前后径活动度和折叠动力学,且差异在术后1年仍持续。
主要发现
- Memo 3D环术后前后径变化百分比为3.7%(SD 2.7) vs 1.9%(SD 1.3),P=0.013;瓣环高度变化为27.7%(SD 8.7) vs 18.0%(SD 13.9),P=0.003。
- Physio II环基线鞍形恢复更优,收缩期瓣环高度与连合宽度比值为15.1%(SD 2.3) vs 7.1%(SD 2.4),P<0.001。
- 术后1年,Memo 3D环前后径延伸为5.1%(SD 1.0) vs 1.7%(SD 1.6),P=0.002;瓣环高度与连合宽度比值变化为15.7%(SD 12.7) vs 3.1%(SD 3.0),P=0.020。
- 两种装置的二尖瓣功能无显著差异。
临床怎么用
- 选择半硬质瓣环成形装置时,需权衡Physio II环的收缩期鞍形恢复优势与Memo 3D环的动态折叠动力学特性,两者二尖瓣功能结果无显著差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The choice of annuloplasty device is fundamental at the time of mitral valve repair, the goal being to optimally restore the physiological 3-dimensional (3D) structure and dynamics of the mitral annulus (MA). This study evaluated MA dynamics after annuloplasty with 2 different semi-rigid devices. METHODS: Thirty-three patients eligible for mitral valve repair were selected for annuloplasty with the Physio II ring (Edwards Lifesciences, Irving, CA, USA) (n = 17) or the Memo 3D ring (LivaNova, Saluggia, Italy) (n = 16). MA dynamics were assessed with transoesophageal 3D echocardiography intraoperatively and 1 year after repair. RESULTS: The postoperative changes in the anteroposterior diameter {3.7% [standard deviation (SD) 2.7] vs 1.9% [SD 1.3]; P = 0.013} and in the annular height [27.7% (SD 8.7) vs 18.0% (SD 13.9); P = 0.003] were significantly larger with the Memo 3D ring during the cardiac cycle. The restoration of the saddle shape at baseline was superior with the Physio II ring, defined by a larger systolic annular height-to-commissural width ratio [15.1% (SD 2.3) vs 7.1% (SD 2.4); P < 0.001]. These observations of MA dynamics were sustained after 1 year, shown by a greater anteroposterior extension [5.1% (SD 1.0) vs 1.7% (SD 1.6); P = 0.002] and change in annular height-to-commissural width ratio [15.7% (SD 12.7) vs 3.1% (SD 3.0); P = 0.020] for the Memo 3D ring. There were no significant differences in mitral valve function between the 2 devices. CONCLUSIONS: The MA dynamics after annuloplasty with the Physio II and Memo 3D rings demonstrated a better systolic 3D restoration of the saddle shape with the Physio II ring, whereas the saddle-shaped geometry improved significantly with the Memo 3D ring, as a dynamic phenomenon. The Memo 3D ring also showed increased anteroposterior annular mobility and folding dynamics throughout the cardiac cycle. Moreover, the observed differences in MA dynamics between both devices appeared to be sustainable 1 year after ring implantation.
引用
- Bouchez S, Timmermans F, Philipsen T, et al. Comparison of the sustainability of mitral annular dynamics between two semi-rigid annuloplasty devices. Eur J Cardiothorac Surg. 2019. PMID: 30770923. doi:10.1093/ejcts/ezz035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。