文献速递瓣膜外科主动脉外科

可修复性二叶式主动脉瓣表型的变异性:面向解剖与修复的分类系统

Variability of repairable bicuspid aortic valve phenotypes: towards an anatomical and repair-oriented classification.
PubMed 文献 · Eur J Cardiothorac Surg · 2019-02-20

本研究在178例因主动脉瓣反流或主动脉扩张接受手术的患者中,通过超声和术中测量11项二叶式主动脉瓣解剖参数,依据交界方向将瓣膜分为A型(对称,160-180°)、B型(不对称,140-159°)和C型(极不对称,120-139°),并描述各型解剖特征及修复技术差异,提出以修复为导向的新分类系统。

要点

  • 交界方向与融合长度正相关(R²=0.6),与非功能交界高度负相关(R²=0.45)。
  • 从A型到C型,融合长度和瓣叶几何高度递减,非功能交界高度递增(P<0.05)。
  • C型患者主动脉瓣置换和修复后残余反流更常见(P<0.05)。

核心结论

  • 二叶式主动脉瓣表型呈从对称到极不对称的连续谱,基于交界方向、融合长度和非功能交界高度的新分类可预测修复技术。

研究设计与样本

  • 在2个中心连续纳入178例因主动脉瓣反流或主动脉扩张手术、且判断为潜在可修复的二叶式主动脉瓣患者,术前超声和术中测量11项解剖参数。

主要发现

  • 交界方向与融合长度正相关(R²=0.6,P<0.001),与非功能交界高度负相关(R²=0.45,P<0.001)。
  • 按交界方向分组:A型对称160-180°(n=73)、B型不对称140-159°(n=74)、C型极不对称120-139°(n=31)。
  • 从A型到C型,融合长度和瓣叶几何高度递减,非功能交界高度递增(P<0.05),患者年龄递增。
  • 孤立性主动脉扩张在A型更常见,重度主动脉瓣反流在B型和C型更常见(P<0.05)。
  • C型患者主动脉瓣置换和修复后残余反流更常见(P<0.05)。

关键数值与推荐

  • 交界方向分组标准:A型160-180°、B型140-159°、C型120-139°。
  • 瓣膜修复技术及交界方向处理在三组间存在差异(P<0.05)。

临床怎么用

  • 术前可通过交界方向等解剖参数对二叶式主动脉瓣分型,预判修复策略及残余反流风险。

局限性

  • 新分类系统需进一步在外科技术和长期结局方面验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES:: The bicuspid aortic valve (BAV) exists in a wide variety of valve phenotypes. The aim of this study was to assess the anatomical characteristics of the different phenotypes and develop a classification system to aid surgical repair. METHODS:: In 178 consecutive patients operated on for aortic insufficiency or aortic dilatation in 2 centres, 11 anatomical parameters of BAV were measured by echocardiography and intraoperatively. All BAV judged potentially repairable were included in the study. RESULTS:: Commissural orientation correlated positively with fusion length (R2 = 0.6, P < 0.001) and negatively with non-functional commissure height (R2 = 0.45, P < 0.001). The cohort was divided into 3 groups according to their commissural orientation (type A: symmetrical, 160-180°, n = 73; type B: asymmetrical, 140-159°, n = 74; and type C: very asymmetrical, 120-139°, n = 31). The patterns of cusp fusion, annulus and aortic size were similar among the groups. Fusion length and the geometric height of the cusps decreased from type A to C; non-functional commissure height increased from type A to C (P < 0.05). Patient age increased from type A to type C. Isolated aortic dilatation was more frequent in type A, and severe aortic insufficiency was more frequent in types B and C (P < 0.05). Valve repair techniques and management of commissural orientation varied among the 3 groups (P < 0.05). Aortic valve replacement and residual aortic insufficiency after repair were more frequent in type C (P < 0.05). CONCLUSIONS:: The BAV phenotypes follow a continuous spectrum that extends from symmetrical to very asymmetrical BAV. We describe the main anatomical parameters (including commissure orientation, length of fusion and non-functional commissure height) and their variation across this spectrum. We propose a new repair-oriented classification system based on those parameters that can be used to predict valve repair techniques. This classification needs further validation with regards to surgical techniques and long-term outcomes.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. de Kerchove L, Mastrobuoni S, Froede L, et al. Variability of repairable bicuspid aortic valve phenotypes: towards an anatomical and repair-oriented classification. Eur J Cardiothorac Surg. 2019. PMID: 30789231. doi:10.1093/ejcts/ezz033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。