文献速递主动脉外科

马凡综合征A型主动脉夹层行象鼻支架与全弓置换后远端主动脉转归

Fate of distal aorta after frozen elephant trunk and total arch replacement for type A aortic dissection in Marfan syndrome.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-08-24

该回顾性队列纳入2003至2015年172例马凡综合征A型主动脉夹层行 frozen elephant trunk(FET)加全弓置换的患者(急性94例、慢性78例),平均随访6.2年。术后假腔闭塞率自支架段向远端递减,真腔各段均随时间扩大;远端主动脉最大径在降主动脉和膈肌水平仍增长。术前远端最大径和降主动脉假腔通畅可预测扩张与再手术。

要点

  • FET加全弓置换后真腔各段均扩大,支架段假腔缩小,远端假腔稳定。
  • 降主动脉和膈肌水平最大主动脉径仍随时间增长,需长期影像随访。
  • 降主动脉假腔通畅与扩张、再手术和晚期死亡风险升高相关。

核心结论

  • FET可扩大全程真腔、减小或稳定假腔并稳定远端主动脉,诱导马凡综合征A型夹层远端主动脉有利重塑。
  • 本研究提供长期临床与影像学证据支持FET用于马凡综合征A型夹层。

研究设计与样本

  • 回顾性队列研究,2003至2015年纳入172例马凡综合征A型主动脉夹层行FET加全弓置换患者,其中急性94例、慢性78例。
  • 平均年龄34.6±9.3岁,男性121例(70.3%)。
  • 早期死亡8.1%(14/172),随访完整率98.7%(156/158),平均随访6.2±3.3年。
  • 主动脉扩张定义为CT血管造影任一节段最大径大于50 mm或平均增长率大于5 mm/年。
  • 采用线性混合模型分析假腔、真腔和最大主动脉径的时间变化。

主要发现

  • 术后假腔闭塞率在FET段、非支架降主动脉、膈肌和肾动脉水平分别为86%、39%、26%和21%。
  • 真腔各段随时间显著扩大(P < .001);假腔在FET段缩小(P < .001),远端各段稳定(P > .05)。
  • 最大主动脉径在FET段和肾动脉水平稳定(P > .05),在降主动脉(P = .001)和膈肌水平(P < .001)增长。
  • 出院前各段最大主动脉径分别为40.2 mm、32.1 mm、31.6 mm和26.9 mm,增长率分别为0.4 mm/年、2.8 mm/年、3.6 mm/年和2.6 mm/年。
  • 末次随访时远端最大主动脉径稳定者占63.5%(99/156),完全重塑至中段降主动脉者占28.8%(45/156);晚期死亡22例,远端再手术23例。

临床怎么用

  • 对马凡综合征A型夹层行FET加全弓置换后应长期影像随访远端主动脉,重点监测降主动脉和膈肌水平最大径变化。
  • 术前远端最大主动脉径较大或降主动脉假腔持续通畅者,扩张、再手术和晚期死亡风险较高,应加强监测与干预评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The use of the frozen elephant trunk technique for type A aortic dissection in Marfan syndrome is limited by the lack of imaging evidence for long-term aortic remodeling. We seek to evaluate the changes of the distal aorta and late outcomes after frozen elephant trunk and total arch replacement for type A aortic dissection in patients with Marfan syndrome. METHODS: Between 2003 and 2015, we performed frozen elephant trunk + total arch replacement for 172 patients with Marfan syndrome suffering from type A aortic dissection (94 acute; 78 chronic). Mean age was 34.6 ± 9.3 years, and 121 were male (70.3%). Early mortality was 8.1% (14/172), and follow-up was complete in 98.7% (156/158) at a mean of 6.2 ± 3.3 years. Aortic dilatation was defined as a maximal diameter of greater than 50 mm or an average growth rate of greater than 5 mm/year at any segment detected by computed tomographic angiography. Temporal changes in the false and true lumens and maximal aortic size were analyzed with linear mixed modeling. RESULTS: After surgery, false lumen obliteration occurred in 86%, 39%, 26%, and 21% at the frozen elephant trunk, unstented descending aorta, diaphragm, and renal artery, respectively. The true lumen expanded significantly over time at all segments (P < .001), whereas the false lumen shrank at the frozen elephant trunk (P < .001) and was stable at distal levels (P > .05). Maximal aortic size was stable at the frozen elephant trunk and renal artery (P > .05), but grew at the descending aorta (P = .001) and diaphragm (P < .001). Respective maximal aortic sizes before discharge were 40.2 mm, 32.1 mm, 31.6 mm, and 26.9 mm, and growth rate was 0.4 mm/year, 2.8 mm/year, 3.6 mm/year, and 2.6 mm/year. By the latest follow-up, distal maximal aortic size was stable in 63.5% (99/156), and complete remodeling down to the mid-descending aorta occurred in 28.8% (45/156). There were 22 late deaths and 23 distal reoperations. Eight-year incidence of death was 15%, reoperation rate was 20%, and event-free survival was 65%. Preoperative distal maximal aortic size (mm) predicted dilatation (hazard ratio, 1.11; P < .001) and reoperation (hazard ratio, 1.07; P < .001). A patent false lumen in the descending aorta predicted dilatation (hazard ratio, 3.88; P < .001), reoperation (hazard ratio, 3.36; P = .014), and late death (hazard ratio, 3.31; P = .045). CONCLUSIONS: The frozen elephant trunk technique can expand the true lumen across the aorta, decrease or stabilize the false lumen, and stabilize the distal aorta in patients with Marfan syndrome with type A aortic dissection, thereby inducing favorable remodeling in the distal aorta. This study adds long-term clinical and radiologic evidence supporting the use of the frozen elephant trunk technique for type A dissection in Marfan syndrome.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Chen Y, Ma WG, Zhi AH, et al. Fate of distal aorta after frozen elephant trunk and total arch replacement for type A aortic dissection in Marfan syndrome. J Thorac Cardiovasc Surg. 2018. PMID: 30635189. doi:10.1016/j.jtcvs.2018.07.096

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。