主动脉根部同种移植物衰败后再次主动脉瓣置换:经导管与外科换瓣的对比
该回顾性研究比较了51例主动脉根部同种移植物衰败患者再次行主动脉瓣置换的结果,其中经导管主动脉瓣置换11例、外科主动脉瓣置换40例。两组手术相关死亡相似,但经导管组血管损伤更常见,外科组大出血和胸骨再入损伤更常见。总体而言,无论采用何种技术,再次换瓣均有显著的并发症和死亡风险。
要点
- 经导管组血管损伤发生率高于外科组(36% vs 5%)。
- 外科组大出血或危及生命出血发生率高于经导管组(58% vs 0%)。
- 两组手术相关死亡相似(外科8% vs 经导管9%)。
核心结论
- 主动脉根部同种移植物衰败后再次主动脉瓣置换,无论经导管还是外科技术,均有显著的并发症和死亡风险。
- 避免血管损伤可能改善经导管主动脉瓣置换组的结果。
主要发现
- 患者年龄59岁(四分位距50-72岁),女性9例(18%),距再次主动脉瓣置换时间12年(四分位距8-13年)。
- 手术相关并发症37例(73%):血管损伤(任何)经导管组更常见(36% vs 5%;P = .015)。
- 出血(主要或危及生命)外科组更常见(58% vs 0%;P < .001)。
- 胸骨再入损伤仅见于外科组(6例,15%)。
- 手术相关死亡外科组3例(8%),经导管组1例(9%)(P = 1.000);后续心脏手术经导管组无,外科组5例。
临床怎么用
- 对于主动脉根部同种移植物衰败患者,选择再次换瓣方式时应权衡血管损伤与出血/胸骨再入损伤的风险。
- 经导管途径需注意规避血管损伤,外科途径需警惕大出血和胸骨再入损伤。
局限性
- 回顾性研究,样本量小(51例),经导管组仅11例且时间跨度不同,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Published data are limited in comparison of transcatheter aortic valve replacement with surgical aortic valve replacement for the failing aortic root homograft. We reviewed our experience with repeat aortic valve replacement in failing aortic root homografts to compare outcomes of transcatheter aortic valve replacement and surgical aortic valve replacement. METHODS: We retrospectively reviewed the records of 51 patients with failing aortic root homografts who received repeat aortic valve replacement between October 2000 and May 2018. Operation included transcatheter aortic valve replacement in 11 patients between June 2014 and May 2018. Surgical aortic valve replacement was performed in 40 patients between October 2000 and January 2018, and operation included repeat composite aortic valve/root replacement in 30 patients (75%). RESULTS: Patient age was 59 years (interquartile range, 50-72 years), sex was female in 9 patients (18%), and time to repeat aortic valve replacement was 12 years (interquartile range, 8-13). Procedure-related complications occurred in 37 patients (73%): vascular injury (any) more commonly in the transcatheter aortic valve replacement group (36% vs 5%; P = .015), bleeding (major or life-threatening) more commonly in the surgical aortic valve replacement group (58% vs 0%; P < .001), and sternal reentry injury only in the surgical aortic valve replacement group (n = 6, 15%). There were 3 procedure-related deaths in the surgical aortic valve replacement group (8%) and 1 (9%) in the transcatheter aortic valve replacement group (P = 1.000). Subsequent cardiac operation occurred in no patients in the transcatheter aortic valve replacement group and in 5 patients in the surgical aortic valve replacement group. CONCLUSIONS: Repeat aortic valve replacement for failing aortic root homograft is associated with notable risk of morbidity and mortality regardless of replacement technique. Avoidance of vascular injury could lead to improved outcomes in the transcatheter aortic valve replacement group.
引用
- Sedeek AF, Greason KL, Nkomo VT, et al. Repeat aortic valve replacement for failing aortic root homograft. J Thorac Cardiovasc Surg. 2018. PMID: 30665760. doi:10.1016/j.jtcvs.2018.11.107
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。