瓣膜与瓣下联合修复后缺血性二尖瓣反流复发风险
本文为乳头肌靠拢随机试验的事后分析,纳入48例重度缺血性二尖瓣反流行冠脉搭桥联合二尖瓣修复加乳头肌靠拢术患者。术前肺动脉收缩压、二尖瓣帐篷面积、对称性牵拉模式及左室舒张末径与随访反流分级相关,联合帐篷面积≥3.1 cm2与左室舒张末径≥64 mm可识别复发高危患者。
要点
- 术前二尖瓣帐篷面积≥3.1 cm2且左室舒张末径≥64 mm提示反流复发高危。
- 肺动脉收缩压、帐篷面积、对称性牵拉及左室舒张末径与随访反流分级相关。
- 该模型预测中重度反流复发的特异性92%、敏感性69%。
核心结论
- 冠脉搭桥联合二尖瓣修复加乳头肌靠拢术后,基线二尖瓣装置与左室几何重构程度可识别反流复发风险增加的患者。
研究设计与样本
- 乳头肌靠拢随机试验的事后分析,纳入48例重度缺血性二尖瓣反流行冠脉搭桥联合二尖瓣修复加乳头肌靠拢术患者,平均年龄63±7岁。
主要发现
- 37例有基线与5年随访超声心动图,中重度二尖瓣反流复发率为27%。
- 线性回归显示术前肺动脉收缩压(β=0.49/mm Hg,p=0.002)、二尖瓣帐篷面积(β=0.47/cm2,p=0.004)、对称性二尖瓣牵拉模式(β=0.44,p=0.007)及左室舒张末径(β=0.37/mm,p=0.02)与随访反流分级相关。
关键数值与推荐
- 二尖瓣帐篷面积≥3.1 cm2(AUC 0.822)与左室舒张末径≥64 mm(AUC 0.801)联合模型预测中重度反流复发:特异性92%、敏感性69%、AUC 0.804、p=0.003。
临床怎么用
- 术前超声评估二尖瓣帐篷面积、左室舒张末径、肺动脉收缩压及牵拉模式,有助于筛选冠脉搭桥联合二尖瓣修复加乳头肌靠拢术后反流复发高危患者。
局限性
- 本文为事后分析,样本量48例,仅37例有5年随访超声心动图。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Mitral valve repair (MVr) combined with papillary muscle approximation (PMA) may improve repair durability in severe ischemic mitral regurgitation (MR), when compared with MVr alone. We sought to identify preoperative transthoracic echocardiographic markers associated with MR recurrence after MVr with PMA. METHODS: A post-hoc analysis was performed on patients with severe ischemic MR who underwent coronary artery bypass graft surgery with MVr with PMA in the papillary muscle approximation randomized trial. The PMA was performed utilizing a 4-mm polytetrafluoroethylene graft placed around the papillary muscles. Linear regression analyses and receiver-operating characteristic curves were used to identify echocardiographic variables and diagnostic models associated with recurrent MR. RESULTS: There were 48 patients with a mean age of 63 ± 7 years, a left ventricular ejection fraction of 35% ± 5%, and a left ventricular end-diastolic diameter of 63 ± 3 mm. Of these, 37 patients had baseline and 5-year follow-up echocardiograms, with moderate-to-severe MR recurring in 27%. Linear regression analyses revealed associations between preoperative pulmonary artery systolic pressure (standardized beta coefficient, β = 0.49/mm Hg, p = 0.002), MV tenting area (β = 0.47/cm2, p = 0.004), a symmetric MV tethering pattern (β = 0.44, p = 0.007), and left ventricular end-diastolic diameter (β = 0.37/mm, p = 0.02) with follow-up MR grade. The presence of both MV tenting area 3.1 cm2 or greater (area under the curve 0.822) and left ventricular end-diastolic diameter of 64 mm or greater (area under the curve 0.801) was the most robust discriminative model for moderate-to-severe MR recurrence (specificity 92%, sensitivity 69%, area under the curve 0.804, p = 0.003). CONCLUSIONS: In patients undergoing coronary artery bypass graft surgery with MVr plus PMA, the extent of baseline MV apparatus and left ventricle geometric remodeling identifies patients at increased risk for MR recurrence.
引用
- Nappi F, Lusini M, Avtaar Singh SS, et al. Risk of Ischemic Mitral Regurgitation Recurrence After Combined Valvular and Subvalvular Repair. Ann Thorac Surg. 2019. PMID: 30684477. doi:10.1016/j.athoracsur.2018.12.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。