文献速递心外重症与机械循环支持

轴流式连续流左心室辅助装置患者系列门诊血压测量的预后意义

Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device.
PubMed 文献 · J Heart Lung Transplant · 2018-11-15

该回顾性研究纳入220例HeartMate II左心室辅助装置患者,分析系列门诊血压均值与访视间变异性和卒中或疑似泵血栓复合终点的关联。结果显示高平均动脉压组复合终点风险显著升高,高收缩压与卒中风险增加相关,低脉压和低访视间血压变异性可能带来额外风险。

要点

  • 高平均动脉压(>90 mm Hg)与卒中或疑似泵血栓风险增加独立相关。
  • 高收缩压(≥101 mm Hg)患者卒中风险较低收缩压者升高。
  • 低脉压(<22 mm Hg)合并高收缩压时卒中风险最高,低访视间血压变异性亦与最高风险相关。

核心结论

  • 门诊血压升高与HeartMate II recipients卒中或疑似泵血栓风险增加相关。
  • 脉压降低和访视间血压变异性低可能带来额外风险。

研究设计与样本

  • 回顾性研究,纳入220例HeartMate II患者,对系列门诊血压测量值取平均。
  • 按平均动脉压、收缩压和脉压分组,并按平均动脉压和收缩压标准差四分位评估访视间血压变异性。
  • 主要终点为卒中或疑似泵血栓的复合终点。

主要发现

  • 高平均动脉压组主要终点风险较中间平均动脉压组升高(校正HR 2.75,95%CI 1.49至5.05),较低平均动脉压组升高(校正HR 6.73,95%CI 1.9至23.9)。
  • 平均动脉压对主要终点的预测价值高于收缩压(p=0.05)。
  • 高收缩压患者卒中风险较低收缩压者升高(HR 2.8,95%CI 1.09至7.17)。
  • 高收缩压合并低脉压与卒中风险最高相关。
  • 访视间平均动脉压变异性最低四分位与主要终点风险最高相关。

临床怎么用

  • 对HeartMate II患者应关注门诊平均动脉压和收缩压水平,高值可能提示卒中或泵血栓风险增加。
  • 评估风险时除血压均值外,还需注意脉压偏低和访视间血压变异性低的情况。

局限性

  • 回顾性研究设计。
  • 单中心、特定装置(HeartMate II)人群,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Elevated blood pressure (BP) has been linked to adverse events during left ventricular assist device support. In this study we investigated the association between outpatient BP and stroke or suspected pump thrombosis among HeartMate II (HMII) recipients. METHODS: We retrospectively studied 220 HMII patients. Serial outpatient BP measurements were averaged. Patients were categorized by: (1) mean arterial pressure (MAP), high (>90 mm Hg) vs intermediate (80 mm Hg ≤ MAP ≤ 90 mm Hg) vs low (<80 mm Hg); (2) systolic BP (SBP), high (≥101 mm Hg, median) vs low; and (3) pulse pressure (PP), high (≥22 mm Hg, median) vs low. To assess visit-to-visit BP variability, patients were divided in quartiles of standard deviation of MAP and SBP. The primary end-point was the composite of stroke or suspected pump thrombosis. RESULTS: The risk for the primary end-point was increased in the high MAP group (adjusted hazard ratio [HR] 2.75, 95% confidence interval [CI] 1.49 to 5.05, vs intermediate MAP; and 6.73, 1.9 to 23.9, vs low MAP). MAP had higher predictive value for the primary end-point compared with SBP (p = 0.05). Patients with high SBP had a higher rate of stroke (HR 2.8, 95% CI 1.09 to 7.17, vs low SBP). The combination of high SBP and low PP was associated with the highest risk for stroke. The lowest quartile of visit-to-visit MAP variability was associated with the highest risk for the primary end-point. CONCLUSIONS: Elevated outpatient BP is associated with increased risk for stroke or suspected pump thrombosis in HMII recipients. Reduced PP and low visit-to-visit BP variability may confer additional risk.

来源:J Heart Lung Transplant,查看原文。版权归原作者所有。

引用

  1. Pinsino A, Castagna F, Zuver AM, et al. Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device. J Heart Lung Transplant. 2018. PMID: 30559034. doi:10.1016/j.healun.2018.11.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。