文献速递心外重症与机械循环支持

儿童机械循环支持期间获得性血管性血友病综合征

Acquired von Willebrand syndrome in paediatric patients during mechanical circulatory support.
PubMed 文献 · Eur J Cardiothorac Surg · 2019-01-01

该单中心观察性研究纳入30例接受机械循环支持的儿童,发现所有患儿均出现获得性血管性血友病综合征(AVWS),表现为高分子量血管性血友病因子多聚体丢失及胶原结合能力下降;

要点

  • 儿童机械循环支持期间AVWS发生率为100%,装置撤除后消失。
  • 出血并发症常见,约53%需外科干预,但无出血相关死亡。
  • AVWS患者出血倾向差异大,需个体化评估。

核心结论

  • 儿童机械循环支持期间获得性血管性血友病综合征患病率为100%,与装置类型无关。
  • AVWS患者出血倾向差异较大,但无出血相关死亡。

研究设计与样本

  • 单中心观察性研究,纳入30例接受机械循环支持的儿童(体外生命支持13例,体外膜氧合5例,心室辅助装置12例)。
  • 检测血管性血友病因子参数(胶原结合能力、胶原结合能力与抗原比值、高分子量多聚体)并记录出血事件等。

主要发现

  • 所有患儿均在机械循环支持期间出现AVWS,通常于术后早期,装置撤除后无AVWS。
  • 检测到高分子量血管性血友病因子多聚体丢失、胶原结合能力与抗原比值降低及胶原结合能力水平降低。

临床怎么用

  • 对机械循环支持的儿童应监测AVWS相关指标,以便风险分层和出血管理。

局限性

  • 单中心观察性研究,样本量30例,结论需更大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Bleeding signs can become life-threatening complications in patients on mechanical circulatory support (MCS). Clinical phenotyping and comprehensive analyses of the cause of bleeding are, therefore, essential, especially when risk-stratifying patients during MCS workup. We conducted coagulation analyses and determined von Willebrand factor (VWF) parameters in a paediatric cohort on temporary extracorporeal life support, extracorporeal membrane oxygenation or long-term ventricular assist device support. METHODS: We carried out an observational single-centre study including 30 children with MCS (extracorporeal life support, n = 13; extracorporeal membrane oxygenation, n = 5; and ventricular assist device, n = 12). We also assessed the acquired von Willebrand parameters of each study participant: collagen binding capacity (VWF:CB), the ratio of collagen-binding capacity to VWF antigen (VWF:CB/VWF:Ag) and high-molecular-weight VWF multimers. We also documented bleeding events, transfusion requirement, haemolysis parameters and surgical interventions. RESULTS: All children developed AVWS (acquired von Willebrand syndrome) during MCS, usually during the early postoperative course. They presented no AVWS after device explantation. We detected a loss of high-molecular-weight VWF multimers, decreased VWF:CB/VWF:Ag ratios and reduced VWF:CB levels. Twenty of the 30 patients experienced bleeding complications; approximately 53% of them required surgical revision. There were no deaths due to bleeding during support. CONCLUSIONS: The AVWS prevalence in paediatric patients on MCS is 100% regardless of the types of devices tested in this study. The bleeding propensity of AVWS patients widely varies.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Kubicki R, Stiller B, Kroll J, et al. Acquired von Willebrand syndrome in paediatric patients during mechanical circulatory support. Eur J Cardiothorac Surg. 2019. PMID: 30590475. doi:10.1093/ejcts/ezy408

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。