三维二尖瓣结构预测冠脉搭桥后中度缺血性二尖瓣反流改善
本研究纳入143例既往心肌梗死合并中度缺血性二尖瓣反流(IMR)行非体外循环冠状动脉旁路移植术(OPCAB)患者,分析术前三维超声二尖瓣环几何与瓣叶牵拉模型。随访1年,65例IMR改善(无或轻度),70例失败(中度或重度)。非平面角(P < .001)和P3牵拉角(P < .001)是中度IMR改善的独立预测因子。
要点
- 术前三维超声评估二尖瓣环非平面角和P3牵拉角可预测OPCAB后中度IMR改善。
- 非平面角158.1°(敏感度64.3%,特异度86.2%)为切点值。
- P3牵拉角28.8°(敏感度78.6%,特异度84.6%)为切点值。
核心结论
- 术前中度IMR在部分患者中可通过OPCAB改善。
- 较小的瓣环扁平化(较小的非平面角)和较少的P3瓣叶牵拉可预测OPCAB后中度IMR改善。
研究设计与样本
- 回顾性分析143例既往心肌梗死合并中度IMR行OPCAB患者,年龄67.6 ± 7.6岁,女性占32.9%。
- 分析术前三维超声二尖瓣环几何和瓣叶牵拉模型,根据术后1年随访IMR分组比较。
主要发现
- 术后1年,改善组65例(无或轻度IMR),失败组70例(中度或重度IMR)。
- 改善组术前瓣环扁平化程度更轻(非平面角更小),且A3、P1、P2、P3牵拉角更小。
- 非平面角(P < .001)和P3牵拉角(P < .001)是中度IMR改善的独立预测因子。
关键数值与推荐
- P3牵拉角切点值28.8°,敏感度78.6%,特异度84.6%。
- 非平面角切点值158.1°,敏感度64.3%,特异度86.2%。
临床怎么用
- 术前三维超声测量二尖瓣环非平面角和P3牵拉角,有助于识别OPCAB后中度IMR可能改善的患者。
- 对于瓣环扁平化轻、P3牵拉小的患者,可预期OPCAB后IMR改善,或可避免同期二尖瓣手术。
局限性
- 1年内8例死亡,可能影响分组分析。
- 样本量有限,单中心研究,结论需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Focusing on 3-dimensional mitral valve structure, this study investigated predictors for moderate ischemic mitral regurgitation (IMR) improvement after off-pump coronary artery bypass grafting (OPCAB). METHODS: This study included 143 patients (age 67.6 ± 7.6 years, 32.9% female) with previous myocardial infarction and moderate IMR undergoing OPCAB. Preoperative 3-dimensional echocardiographic data were analyzed, focusing on mitral annular geometry and leaflet tethering model. Patients were grouped according to IMR at 1-year postoperative follow-up into improved (n = 65), with no or mild IMR, and failure (n = 70), with moderate or severe IMR, groups. Groups were compared to identify predictors of IMR improvement after OPCAB. RESULTS: Eight patients died within 1 year. At 1 postoperative year, improved group included 65 patients; failure group included 70. Improved group had less preoperative annular flattening (smaller nonplanar angle) and segmental leaflet tethering (smaller A3, P1, P2, and P3 tethering angles) than failure group. Nonplanar angle (P < .001) and P3 tethering angle (P < .001) were independent predictors of moderate IMR improvement after OPCAB. Receiver operator characteristic curves defined P3 tethering angle of 28.8° (sensitivity of 78.6%, specificity of 84.6%) and nonplanar angle of 158.1° (sensitivity, 64.3% and specificity of 86.2%) as the cutoff values. CONCLUSIONS: Preoperative moderate IMR can be improved by OPCAB in selected patients. Less annular flattening and P3 leaflet tethering may predict improvement of moderate IMR after OPCAB, suggesting that the annular nonplanar saddle shape and less leaflet tethering toward P3 segment are important for the prognosis of moderate IMR.
引用
- Sun X, Jiang Y, Huang G, et al. Three-dimensional mitral valve structure in predicting moderate ischemic mitral regurgitation improvement after coronary artery bypass grafting. J Thorac Cardiovasc Surg. 2018. PMID: 30527723. doi:10.1016/j.jtcvs.2018.09.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。