文献速递心外重症与机械循环支持

左心室辅助装置植入患者右心室负荷适应指标验证

Right ventricular load adaptability metrics in patients undergoing left ventricular assist device implantation.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-09-25

回顾性纳入194例连续流左心室辅助装置植入患者,验证右心负荷适应指标对术后右心衰竭的预测价值。30天内30例需右心室辅助装置(RVAD),75例发生右心衰竭综合征。右房压、右房压与肺动脉楔压比值及脉压与右房压比值<2.0与RVAD需求相关,但适应指标相比简单指标未显示强增量价值。

要点

  • 右房压、右房压/肺动脉楔压比值及脉压/右房压<2.0与30天内RVAD需求独立相关。
  • 上述3项指标对INTERMACS评分有相似增量预后价值,仅右房压对Michigan评分有增量。
  • 右心负荷适应指标未较简单指标提供更强增量价值。

核心结论

  • 右心负荷适应指标虽与结局相关,但相比简单指标未提供强增量价值。

研究设计与样本

  • 回顾性研究,纳入194例连续流左心室辅助装置植入患者。

主要发现

  • 平均年龄55±13岁,77%为男性;75例发生右心衰竭,30例需RVAD植入。
  • 上述3项指标对INTERMACS评分有相似增量预后价值,仅右房压对Michigan评分有增量。
  • 不需RVAD的右心衰竭相关因素包括右室收缩末面积指数和Dandel指数,对INTERMACS、Michigan和EUROMACS评分提供相似增量价值。

临床怎么用

  • 临床可优先使用右房压、右房压/肺动脉楔压比值及脉压/右房压<2.0等简单指标评估RVAD需求风险。

局限性

  • 回顾性研究设计可能带来选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Several right load adaptability metrics have been proposed as predictors of right heart failure (RHF) following left ventricular assist device implantation. This study sought to validate and compare the prognostic value of these indices. METHODS: This retrospective study included 194 patients undergoing continuous-flow left ventricular assist device implantation. The primary end point was unplanned right atrial assist device (RVAD) need within 30 days after left ventricular assist device implantation; the secondary end points included clinical RHF syndrome without RVAD need and the composite of RHF or RVAD need. Load adaptability indices or interventricular ratios were divided into surrogates of ventriculoarterial coupling (RV area change:end-systolic area), indices reflecting adaptation proportionality (Dandel's index = tricuspid regurgitation velocity-time integral normalized for average RV radius in diastole or systole), and simple ratios (eg, pulse pressure:right atrial pressure or right arterial pressure:pulmonary arterial wedge pressure). RESULTS: Mean age was 55 ± 13 years with 77% of men. RHF occurred in 75 patients with 30 patients requiring RVAD implantation. Among right heart metrics, right arterial pressure (normalized odd ratio, 1.62; 95% confidence interval, 1.15-2.38), right arterial pressure:pulmonary arterial wedge pressure (normalized odds ratio, 1.59; 95% confidence interval, 1.08-2.32) and pulse pressure:right arterial pressure < 2.0 (normalized odds ratio, 2.56; 95% confidence interval, 1.16-5.56) were associated with RVAD need (all P values < .02). These 3 metrics significantly added incremental prognostic value to the Interagency Registry for Mechanically Assisted Circulatory Support classification score in a similar range, whereas only RAP was incremental to the Michigan score. Correlates of RHF not requiring RVAD included RV end-systolic area index and the Dandel indices, which provided similar incremental value to the Interagency Registry for Mechanically Assisted Circulatory Support, Michigan, and European Registry for Patients with Mechanical Circulatory Support scores. CONCLUSIONS: Although associated with outcome, right load adaptability indices do not appear to provide strong incremental value when compared with simple metrics.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Amsallem M, Aymami M, Hiesinger W, et al. Right ventricular load adaptability metrics in patients undergoing left ventricular assist device implantation. J Thorac Cardiovasc Surg. 2018. PMID: 30482529. doi:10.1016/j.jtcvs.2018.08.095

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。