文献速递肺外科

低负压吸引对VATS肺叶切除术后数字引流装置的影响:随机对照试验

The effects of low suction on digital drainage devices after lobectomy using video-assisted thoracoscopic surgery: a randomized controlled trial†.
PubMed 文献 · Eur J Cardiothorac Surg · 2019-01-01

主要结局为胸管拔除时间,低负压组显著缩短引流持续时间、漏气停止时间及总引流量,且未增加并发症。

要点

  • 低负压-2 cmH2O较-10 cmH2O缩短引流持续时间(中位27.4 h vs 47.5 h,P=0.047)。
  • 低负压组漏气停止时间更短(中位5.2 h vs 23.7 h,P<0.001),总引流量更少(P=0.007)。
  • 两组术后并发症、气胸或皮下气肿比例及大小无差异,住院时间无差异(P=0.18)。

核心结论

  • VATS肺叶切除术后使用数字引流装置,低负压-2 cmH2O较-10 cmH2O显著缩短引流时间、漏气停止时间和总引流量,且不增加并发症。

研究设计与样本

  • 主要结局为胸管拔除时间,随访至术后第30天。

主要发现

  • 引流持续时间中位数(四分位距):-2 cmH2O组27.4 h(23.3-71.2),-10 cmH2O组47.5 h(24.5-117.8),P=0.047。
  • 漏气>5天的发生率:-2 cmH2O组14.4%,-10 cmH2O组24.3%,P=0.089。
  • 总引流量中位数(四分位距):-2 cmH2O组566 ml(329-1155),-10 cmH2O组795 ml(454-1605),P=0.007。
  • 漏气停止(<20 ml/min)时间中位数(四分位距):-2 cmH2O组5.2 h(0.3-34.2),-10 cmH2O组23.7 h(0.8-90.8),P<0.001。
  • 拔管后气胸或皮下气肿比例及大小无差异,术后并发症无差异;住院时间中位数(四分位距):-2 cmH2O组2.0天(2.0-5.8),-10 cmH2O组3.0天(2.0-9.0),P=0.18。

临床怎么用

  • VATS肺叶切除术后使用数字引流装置时,可考虑采用低负压-2 cmH2O以缩短引流时间和漏气停止时间,且不增加并发症。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The optimal level of suction on digital chest drainage devices after lobectomy using video-assisted thoracoscopic surgery (VATS) is unknown and varies between thoracic centres. In this randomized controlled trial, we assessed the potential benefits of low suction of -2 cmH2O compared to -10 cmH2O, using a digital drainage device. METHODS: Two hundred and twenty-eight patients were randomized into 2 groups after VATS lobectomy for suspected or confirmed lung cancer. Primary outcome was time to chest drain removal. Drain data were obtained from the digital drainage devices, and patient data were obtained from medical records during admission, with a follow-up until postoperative day 30. RESULTS: For the -2 cmH2O and -10 cmH2O groups, median (interquartile range) drainage duration was 27.4 h (23.3-71.2) and 47.5 h (24.5-117.8) (P = 0.047), and the incidence of prolonged air leak >5 days was 14.4% and 24.3% (P = 0.089), respectively. Median total fluid production was 566 h (329-1155) ml and 795 h (454-1605) ml (P = 0.007). Median time to consistent air leak cessation (<20 ml/min) was 5.2 h (0.3-34.2) and 23.7 h (0.8-90.8) (P < 0.001). There were no differences in the proportion or the size of the pneumothorax or subcutaneous emphysema after drain removal, and no differences were observed in postoperative morbidity. Median length of in-hospital stay was 2.0 days (2.0-5.8) and 3.0 days (2.0-9.0) (P = 0.18). CONCLUSIONS: A low suction level significantly shortened drainage duration, time to air leak cessation and total fluid production, without increasing morbidity. CLINICAL TRIAL REGISTRATION NUMBER: NCT02911259.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Holbek BL, Christensen M, Hansen HJ, et al. The effects of low suction on digital drainage devices after lobectomy using video-assisted thoracoscopic surgery: a randomized controlled trial†. Eur J Cardiothorac Surg. 2019. PMID: 30445572. doi:10.1093/ejcts/ezy361

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。