文献速递肺外科

肺血管能量封闭在前瞻性可行性研究中的评估

Prospective feasibility study of sealing pulmonary vessels with energy in lung surgery.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-04-30

这项在两家机构开展的前瞻性注册研究评估了LigaSure能量封闭系统在解剖性肺切除中封闭肺动脉和静脉分支的可行性。队列1(n=128)封闭直径达7mm的血管,第128例发生术后出血后,队列2(n=200)将肺动脉最大直径改为5mm,结果显示无与能量封闭相关的严重并发症,总体术后出血率为0.3%(1/328)。

要点

  • 能量封闭无需加固即可安全处理直径达5mm的肺动脉和7mm的肺静脉。
  • 第128例出血发生在封闭区邻近部位,而非封闭区本身。
  • 队列2中200例患者无与能量封闭相关的严重术后并发症。

核心结论

  • 无需加固的能量封闭在肺切除中可安全处理直径达5mm的肺动脉和达7mm的肺静脉。

研究设计与样本

  • 前瞻性、术前注册研究,在2家机构开展,评估LigaSure能量封闭系统用于解剖性肺切除中肺动脉和静脉分支的可行性。
  • 队列1(n=128)纳入肺动脉直径最大7mm,队列2(n=200)在更改肺动脉最大直径纳入标准为5mm后开展。

主要发现

  • 队列1中216条肺动脉和189条肺静脉接受能量封闭,队列2中250条肺动脉和213条肺静脉接受能量封闭。
  • 总体术后出血率为0.3%(1/328患者)。
  • 队列2的200例患者中无与能量封闭相关的严重术后并发症。
  • 第128例出血经后续检查证实位于封闭区邻近部位。

关键数值与推荐

  • 队列1肺动脉最大直径7mm,队列2肺动脉最大直径5mm,肺静脉最大直径7mm。
  • 能量封闭时不使用缝线结扎等额外加固材料。

临床怎么用

  • 在肺切除中可考虑使用能量封闭系统处理直径达5mm的肺动脉和达7mm的肺静脉,无需额外结扎加固。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Vascular sealing with an energy vessel sealing system during lung resection may allow surgeons to treat small vessels with minimal dissection, possibly decreasing likelihood of injury. Few large prospective trials have examined the proximal sides of vessels not ligated in addition to sealing during surgery. We therefore assessed feasibility of an energy device to seal pulmonary artery and vein branches without further ligation. METHODS: This prospective, preoperative registration study at 2 institutions evaluated safety of energy sealing with the LigaSure (Medtronic, Minneapolis, Minn), with no additional reinforcing material such as suture ligation, for pulmonary vessels as large as 7 mm during anatomic lung resection (cohort 1 study). A postoperative hemorrhage occurred in the 128th case, so a cohort 2 study proceeded after we changed inclusion criterion for pulmonary arteries from a maximum of 7 mm to a maximum of 5 mm. RESULTS: In cohort 1 (n = 128) and cohort 2 (n = 200), 216 and 250 pulmonary arteries and 189 and 213 pulmonary veins, respectively, were treated with energy sealing. Overall postoperative hemorrhage rate was 0.3% (1/328 patients); however, no serious postoperative complications were associated with energy sealing among the 200 patients in cohort 2. Subsequent inspection of the torn artery stump confirmed that the bleeding in the 128th case was in an area adjacent to the sealing zone. CONCLUSIONS: Energy sealing without reinforcement allows secure treatment during lung resection of pulmonary arteries as large as 5 mm in diameter and pulmonary veins as large as 7 mm.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Okada M, Miyata Y, Takamochi K, et al. Prospective feasibility study of sealing pulmonary vessels with energy in lung surgery. J Thorac Cardiovasc Surg. 2018. PMID: 30415901. doi:10.1016/j.jtcvs.2018.02.113

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。