文献速递瓣膜外科

二尖瓣修复术后跨瓣压差升高:手术技术的影响与术后房颤的相关性

Elevated gradient after mitral valve repair: The effect of surgical technique and relevance of postoperative atrial fibrillation.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-09-27

该回顾性研究纳入390例无房颤的退行性二尖瓣反流行二尖瓣修复术患者,出院前超声测跨瓣压差平均3.1±1.2 mmHg。裂口闭合、缘对缘技术、全环成形和较小人工环尺寸与较高压差相关;

要点

  • 裂口闭合、缘对缘、全环成形及较小人工环尺寸增加术后跨瓣压差。
  • 术后跨瓣压差≥4.5 mmHg与中期随访晚期房颤风险显著相关。
  • 改良瓣叶修复与瓣环成形技术以降低压差可能减少晚期房颤。

核心结论

  • 退行性二尖瓣反流行修复术患者可通过改良瓣叶修复和瓣环成形技术降低术后跨瓣压差,从而减少中期随访晚期房颤发生率。

研究设计与样本

  • 回顾性研究,纳入390例因退行性二尖瓣反流行二尖瓣修复术且无房颤的患者。
  • 出院前行经胸超声心动图测量跨瓣压差,随访记录术后6个月内早期房颤和6个月后晚期房颤及临床超声数据。

主要发现

  • 院内死亡率为0,出院前平均跨瓣压差为3.1±1.2 mmHg。
  • 裂口闭合、缘对缘技术、全环成形和较小 indexed prosthetic size 是较高跨瓣压差的危险因素(P均<.05)。
  • 中位随访46个月,总体队列73.1%维持稳定窦性心律,早期房颤发生率为22.7%。
  • 32例(8.5%)发生晚期房颤,晚期房颤与跨瓣压差显著相关(OR 3.93;P=.004)。
  • 最小P值法确定平均压差≥4.5 mmHg为预测晚期房颤的最佳阈值(χ2=40.704;P<.001)。

关键数值与推荐

  • 跨瓣压差≥4.5 mmHg为预测晚期房颤的最佳阈值(χ2=40.704;P<.001)。
  • 晚期房颤与跨瓣压差的OR为3.93(P=.004)。

临床怎么用

  • 二尖瓣修复术中应优先选择能降低术后跨瓣压差的技术,如避免不必要的裂口闭合、缘对缘及全环成形,选择合适尺寸人工环。
  • 术后应关注跨瓣压差,压差≥4.5 mmHg者需加强房颤监测和随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: We sought to investigate the effect of surgical technique in mitral valve repair on postoperative transmitral gradient (PTMG) and the relationship between PTMG and postoperative atrial fibrillation (AF). METHODS: In this retrospective study, 390 patients who underwent mitral valve repair for degenerative mitral regurgitation without AF were included. PTMG was measured using transthoracic echocardiography before patient discharge. At follow-up, occurrences of AF within 6 months of surgery (early AF) and 6 months after surgery (late AF), as well as clinical and echocardiographic data were documented and investigated. RESULTS: The in-hospital mortality was 0, and the mean gradient was 3.1 ± 1.2 mm Hg before patient discharge. The risks for higher PTMG included cleft closure, edge-to-edge technique, full ring annuloplasty, and smaller indexed prosthetic size (P < .05 for all). After a median follow-up of 46 months, stable sinus rhythm was maintained in 73.1% of the overall cohort and early AF occurred in 22.7% of patients. A total of 32 patients (8.5%) had late AF, which was significantly associated with PTMG (odds ratio, 3.93; P = .004). The minimum P value approach identified a mean gradient of ≥4.5 mm Hg as the best threshold for predicting late AF (χ2 = 40.704; P < .001). CONCLUSIONS: Patients who undergo mitral valve repair for degenerative mitral insufficiency might benefit from modification of the existing leaflet repair and annuloplasty techniques to achieve a lower PTMG level, which is associated with a decreased incidence of late AF during midterm follow-up.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Ma W, Shi W, Wu W, et al. Elevated gradient after mitral valve repair: The effect of surgical technique and relevance of postoperative atrial fibrillation. J Thorac Cardiovasc Surg. 2018. PMID: 30385024. doi:10.1016/j.jtcvs.2018.07.107

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。