心脏手术后患者体验:识别改进领域
结果显示低总体评分与低感知整体健康、年轻年龄、延长住院时间及机器人二尖瓣修复独立相关,患者体验的关键驱动因素为护理过渡和药物沟通。
要点
- 低感知整体健康、年轻年龄、延长住院时间和机器人二尖瓣修复与低总体医院评分独立相关。
- TAVR患者总体评分与开放主动脉瓣手术患者相似。
- 改善患者体验的主要目标为护理过渡和药物沟通。
核心结论
- 本机构改善患者体验的主要目标为护理过渡和药物沟通。
- 微创手术(机器人二尖瓣修复、TAVR)与更高患者体验评分无独立关联。
研究设计与样本
- 采用top-box方法将调查结果合并为九个领域,包括总体医院评分(二分类为高与低)。
- 使用多变量逻辑回归分析评估变量与低总体评分的独立关联,并利用领域均值和Spearman相关进行关键驱动分析。
主要发现
- 低总体医院评分独立关联于低感知整体健康(fair或poor vs excellent;OR 5.4;p=0.001)。
- 低总体医院评分独立关联于年轻年龄(18至59岁 vs ≥70岁;OR 1.6;p=0.048)。
- 低总体医院评分独立关联于延长住院时间(OR 1.6;p=0.02)。
- 低总体医院评分独立关联于机器人二尖瓣修复(机器人 vs 开放修复;OR 2.4;p=0.045)。
- TAVR患者总体评分与开放主动脉瓣手术患者相似(OR 0.9;p=0.64)。
关键数值与推荐
- 患者体验的关键驱动因素为护理过渡和药物沟通。
临床怎么用
- 针对护理过渡和药物沟通进行质量改进可能提升心脏手术后患者体验。
- 对于低感知整体健康、年轻、住院时间延长及机器人二尖瓣修复患者,需关注其体验评分。
- 微创手术本身不保证更高患者体验评分,应注重围术期沟通与过渡管理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) is a publicly reported survey of patient experience with in-hospital care. We reviewed institutional HCAHPS survey data to assess our patients' experiences after cardiac surgery and to identify targets for practice improvement. METHODS: We reviewed data from patients undergoing the most common cardiac operations, with dismissal from October 1, 2012 to September 30, 2015. We used top-box methodology to combine survey results into nine domains, including the global (composite) hospital rating, dichotomized as high versus low. Multivariable logistic regression analysis was used to evaluate the independent associations of variables with low global ratings. Key driver analysis using domain means and Spearman correlation between the global rating and the eight other domains identified targets for quality improvement. RESULTS: Among 1,315 surveyed patients a low global hospital rating was independently associated with low perceived overall health (fair or poor vs excellent; odds ratio [OR], 5.4; p = 0.001), younger age (18 to 59 vs ≥70 years; OR, 1.6; p = 0.048), prolonged length of stay (OR, 1.6; p = 0.02), and robotic mitral valve (MV) repair (robotic vs open repair; OR, 2.4; p = 0.045). Patients undergoing transcatheter aortic valve replacement (TAVR) reported global ratings similar to that of patients with open aortic valve operations (OR, 0.9; p = 0.64). Key drivers of patient experience were care transitions and communication regarding medications. CONCLUSIONS: The primary targets of improvement for our institution are care transitions and communications regarding medications. The less-invasive procedures (robotic MV repair, TAVR) were not independently associated with higher patient-experience scores.
引用
- Helder MRK, Schaff HV, Hanson KT, et al. Patient Experience After Cardiac Surgery: Identifying Areas for Improvement. Ann Thorac Surg. 2018. PMID: 30414830. doi:10.1016/j.athoracsur.2018.09.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。