经心尖外置导丝技术用于复杂主动脉疾病的单中心经验
该单中心回顾性研究纳入2015年4月至2017年3月间接受TEVAR并使用经心尖外置导丝(ETAG)技术的5例复杂主动脉解剖患者。所有病例TEVAR完成,输送系统沿主动脉弓小弯侧推进,3例复杂主动脉粥样斑块患者无栓塞并发症;1例主动脉食管瘘患者死于二期食管切除术,2例出现迟发性心脏压塞需引流。
要点
- ETAG技术适用于严重成角、近端锚定区贴近主动脉瓣或有限、复杂粥样斑块等解剖挑战。
- 该技术可避免输送系统接触主动脉弓大弯侧,可能降低复杂弓部粥样斑块相关栓塞风险。
- 5例TEVAR均完成,但1例主动脉食管瘘患者死于二期食管切除术,2例需引流迟发性心脏压塞。
核心结论
- ETAG技术有助于克服TEVAR中多种解剖挑战,避免输送系统接触主动脉弓大弯侧,可能降低复杂弓部粥样斑块相关栓塞风险。
研究设计与样本
- 单中心回顾性研究,回顾2015年4月至2017年3月接受TEVAR的患者,纳入5例使用ETAG技术者。
主要发现
- 所有病例TEVAR完成,ETAG技术均使用,输送系统尖端沿主动脉弓小弯侧推进。
- 3例复杂主动脉粥样斑块患者无栓塞并发症。
- 全部患者存活TEVAR,但1例主动脉食管瘘患者未存活二期食管切除术。
- 术后并发症包括2例迟发性心脏压塞需引流。
关键数值与推荐
- ETAG适应证包括:严重成角主动脉3例、近端锚定区贴近主动脉瓣2例、近端锚定区有限1例、复杂粥样斑块主要位于主动脉大弯侧3例。
临床怎么用
- 对严重成角、近端锚定区贴近主动脉瓣或有限、复杂弓部粥样斑块等TEVAR解剖挑战者可考虑ETAG技术。
- 术中沿主动脉弓小弯侧推进输送系统,并通过推送导丝两端增加贴靠性、辅助尖端回收。
局限性
- 单中心回顾性研究,样本量仅5例,未设对照组。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The through-and-through guidewire technique has been utilized for safe advancement of a high-profile stent graft delivery system through the tortuous aorta. A brachial-to-femoral configuration is most commonly established, but a few alternatives have been described. This study aimed to report our experience with the externalized transapical guidewire (ETAG) technique in patients who underwent thoracic endovascular aortic repair (TEVAR) and to explore its utility, feasibility and safety. METHODS: Patients who underwent TEVAR between April 2015 and March 2017 were retrospectively reviewed, and 5 patients who underwent the procedure with the ETAG technique were found eligible for the study. Indications for the ETAG technique were the following challenging aortic anatomical configurations: (i) severely angulated aorta in 3; (ii) proximity of the proximal landing zone to the aortic valve in 2; (iii) a limited proximal landing zone in 1; and (iv) complex atheroma predominantly on the greater curvature of the aorta in 3 patients. RESULTS: TEVAR was completed in all cases. The ETAG technique was utilized in all patients. The delivery system tip was navigated along the lesser curvature of the aortic arch as it was advanced. During deployment, conformability was increased by pushing both ends of the wire. Tip retrieval was also enhanced in 3 patients. Patients with complex aortic atheroma had no embolic complications. All patients survived TEVAR, but 1 patient with an aorto-oesophageal fistula did not survive the second-stage oesophagectomy. Postoperative complications included delayed cardiac tamponade requiring drainage in 2 patients. CONCLUSIONS: The ETAG technique was useful in overcoming several anatomical challenges encountered during TEVAR. Contact of the delivery system with the greater curvature of the aortic arch could be avoided with this technique, potentially reducing embolization risk related to the complex aortic arch atheroma.
引用
- Murakami T, Morisaki A, Nishimura S, et al. Externalized transapical guidewire technique for complex aortic disease: a single-centre experience. Eur J Cardiothorac Surg. 2019. PMID: 30351405. doi:10.1093/ejcts/ezy349
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。