文献速递主动脉外科

B型主动脉夹层使用裸金属支架可能对远端主动脉带来正向重塑

Bare Metal Stent Use in Type B Aortic Dissection May Offer Positive Remodeling for the Distal Aorta.
PubMed 文献 · Ann Thorac Surg · 2018-08-02

本研究在2013至2016年期间本院收治的213例B型主动脉夹层患者中,对33例复杂急性B型夹层行胸主动脉腔内修复,其中12例为标准组、21例为PETTICOAT组(近端覆膜支架远端加裸金属支架)。6个月时两组胸腹主动脉各水平主动脉直径、真腔直径及真腔比均有显著变化,PETTICOAT组在腹腔干水平的真腔比变化显著大于标准组。

要点

  • 复杂急性B型夹层行PETTICOAT(近端覆膜支架远端加裸金属支架)6个月时胸腹主动脉出现正向重塑。
  • PETTICOAT组与标准组基线特征无差异。
  • 腹腔干水平真腔比变化PETTICOAT组显著大于标准组。

核心结论

  • 在近端胸主动脉覆膜支架远端加裸金属支架的PETTICOAT概念可于6个月时在胸腹主动脉带来正向主动脉重塑。

研究设计与样本

  • 2013至2016年本院共见213例B型主动脉夹层患者,其中33例因复杂急性B型主动脉夹层行胸主动脉腔内修复。
  • 33例中12例行标准胸主动脉腔内修复(标准组),21例在覆膜支架远端加裸金属支架(PETTICOAT组)。
  • 主动脉尺寸基于出院时及6个月时的三维计算机断层扫描测量。

主要发现

  • 标准组与PETTICOAT组基线特征无差异。
  • 6个月时PETTICOAT组与标准组胸腹主动脉各水平的主动脉直径、真腔直径及真腔比均发生显著变化,显示正向重塑。
  • 腹腔干水平真腔比变化PETTICOAT组显著大于标准组。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Thoracic endovascular aortic repair is increasingly used in acute complicated type B aortic dissection. The objective of this study was to demonstrate evidence of aortic remodeling by using a Proximal ExTension to Induce COmplete ATtachment (PETTICOAT) system in patients with acute complicated type B aortic dissections. METHODS: From 2013 to 2016, 213 patients with type B aortic dissection were seen at our institution. A total of 33 of those patients underwent thoracic endografting for complicated acute type B aortic dissection. Of these patients, 12 underwent standard thoracic endovascular aortic repair (standard group), and 21 had an additional bare metal stent distal to the covered endograft (PETTICOAT group). Aortic dimensions were measured on the basis of on three-dimensional computed tomographic scans on discharge and at 6 months. RESULTS: There were no differences in baseline characteristics between the standard group and the PETTICOAT group. At 6 months, both the PETTICOAT and standard groups had significant change in aortic diameter, true lumen diameter, and true lumen ratio throughout the thoracoabdominal aorta demonstrating positive remodeling. The change in true lumen ratio was significantly greater at the level of the celiac artery with the PETTICOAT system when compared with the standard group. CONCLUSIONS: The use of a PETTICOAT concept with an addition of a bare metal stent distal to the proximal thoracic endograft offers positive aortic remodeling in the thoracoabdominal aorta at 6 months.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Sultan I, Dufendach K, Kilic A, et al. Bare Metal Stent Use in Type B Aortic Dissection May Offer Positive Remodeling for the Distal Aorta. Ann Thorac Surg. 2018. PMID: 30077594. doi:10.1016/j.athoracsur.2018.06.042

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。