I型二叶式主动脉瓣修复中环形稳定化的功能结局:瓣下交界区成形术与外环下主动脉环比较

Functional Outcomes of Type I Bicuspid Aortic Valve Repair With Annular Stabilization: Subcommissural Annuloplasty Versus External Subannular Aortic Ring.
PubMed 文献 · Ann Thorac Surg · 2018-08-04

本研究回顾性分析2003至2017年139例I型二叶式主动脉瓣修复患者,其中50例行瓣下交界区成形术(SCA)、24例行外环下主动脉环(ESAR);经超声筛选后SCA组38例、ESAR组20例。结果显示两组术后免于AI>1+均为100%,ESAR组瓣环缩小更显著且平均跨瓣压差更优。

要点

  • 两组术后免于AI大于1+均为100%,反流缩流宽度和偏心度均显著降低。
  • ESAR组术后平均跨瓣压差为7.1±2.5 mm Hg,优于SCA组的11.2±5.7 mm Hg(p=0.003)。
  • ESAR对瓣环的缩小幅度大于SCA,但原文未报告组间比较的P值。

核心结论

  • 在I型二叶式主动脉瓣修复中,ESAR除提供与SCA等同且良好的免于AI效果外,还带来更强的瓣环缩小和更优的跨瓣压差。

研究设计与样本

  • 2003至2017年回顾性分析139例I型二叶式主动脉瓣修复患者,其中50例行SCA、24例行ESAR;排除超声图像不佳者后,SCA组38例、ESAR组20例,对术前术后经食管超声的11项功能性主动脉根部复合体参数进行分析。

主要发现

  • ESAR组术前瓣环(28.3±3.2 mm vs 29.8±3.7 mm,p=0.1)和左心室流出道(28.1±3.5 mm vs 29.8±4.0 mm,p=0.1)直径更大,瓣叶脱垂更重(3.4±1.3 mm vs 4.3±1.3 mm,p=0.02)。
  • 两组术后免于AI大于1+均为100%,反流缩流宽度分别降低3.0±0.6 mm(p<0.001)和3.2±0.4 mm(p<0.001),AI射流偏心度分别改变-24.3±6.5度(p=0.002)和-22.3±7.2度(p=0.01)。
  • 两组左心室尺寸分别缩小7.1±1.2 mm(p<0.001)和8.9±1.9 mm(p<0.001),瓣环分别缩小3.4±0.4 mm(p<0.001)和5.1±2.7 mm(p<0.001)。
  • 两组左心室流出道分别缩小2.3±0.4 mm(p<0.001)和4.4±0.5 mm(p<0.001),瓣叶脱垂程度分别减轻1.6±0.4 mm(p=0.005)和2.1±0.4 mm(p=0.001)。
  • 术后比较显示ESAR组平均跨瓣压差更优(11.2±5.7 mm Hg vs 7.1±2.5 mm Hg,p=0.003),两组免于AI情况相似。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In bicuspid aortic valve patients with nonaneurysmal root (<45 mm) and severe aortic insufficiency (AI), external subannular aortic ring (ESAR) is being increasingly utilized for annular stabilization, compared with traditional subcommissural annuloplasty (SCA). To this date, there is no comparative study assessing functional equivalence or superiority of ESAR over SCA. METHODS: From 2003 to 2017, 139 patients underwent type I bicuspid aortic valve repair, of which 50 patients underwent concomitant SCA and 24 underwent ESAR. Cases with suboptimal echocardiographic imaging were excluded, resulting in 38 patients in the SCA group and 20 patients in ESAR group. Intraoperative transesophageal echocardiography before and after procedure were retrospectively analyzed for 11 parameters in the functional aortic root complex. RESULTS: ESAR patients had larger preoperative annulus (28.3 ± 3.2 mm versus 29.8 ± 3.7 mm, p = 0.1) and left ventricular (LV) outflow tract (28.1 ± 3.5 mm versus 29.8 ± 4.0 mm, p = 0.1) diameters, with greater leaflet prolapse (3.4 ± 1.3 mm versus 4.3 ± 1.3, p = 0.02). In both groups, 100% freedom from AI greater than 1+ was achieved, with significant reduction of vena contracta (-3.0 ± 0.6 mm, p < 0.001; -3.2 ± 0.4 mm, p < 0.001) and level of eccentricity of AI jet (AI angle change: -24.3 ± 6.5 degrees, p = 0.002; -22.3 ± 7.2 degrees, p = 0.01). Reduction in LV dimensions (-7.1 ± 1.2 mm, p < 0.001; -8.9 ± 1.9 mm, p < 0.001), annulus (-3.4 ± 0.4 mm, p < 0.001; -5.1 ± 2.7 mm, p < 0.001), LV outflow tract (-2.3 ± 0.4 mm, p < 0.001; -4.4 ± 0.5 mm, p < 0.001), and degree of leaflet prolapse (-1.6 ± 0.4 mm, p = 0.005; -2.1 ± 0.4 mm, p = 0.001) was achieved in both groups. Comparison of postprocedure outcomes showed improved mean transvalvular gradients in ESAR (11.2 ± 5.7 mm Hg versus 7.1 ± 2.5 mm Hg, p = 0.003), with similar freedom from AI. CONCLUSIONS: In addition to providing equivalent and excellent freedom from AI, ESAR also renders a more robust annular reduction than SCA, along with improved transvalvular gradients.