一种新型胸内食管胃吻合技术的结局
该研究回顾性分析了2009至2015年278例采用「侧侧吻合:吻合器线对吻合器线」(STS)技术行胸内食管胃吻合的Ivor Lewis食管胃切除术患者,吻合口漏发生率为2.9%(8/278),其中3例为I/II级漏且无需干预;吻合口狭窄需扩张者占5.0%(14/278),出院后仅11.1%的患者需要补充空肠造瘘喂养。作者认为该技术取得了优异结果。
要点
- STS胸内食管胃吻合术后吻合口漏发生率为2.9%(8/278),其中3例为I/II级漏且无需干预。
- 良性病变行食管切除者吻合口漏率为6.3%(2/32),恶性病变者为2.4%(6/246),P=0.22。
- 吻合口狭窄需扩张者占5.0%(14/278),中位扩张次数为2次;出院后仅11.1%需补充空肠造瘘喂养。
核心结论
- 作者认为,这种新型STS技术就食管切除术后胸内食管胃吻合口漏和狭窄的发生率而言提供了优异的结果。
- 此外,该技术显著减少了出院后对肠内喂养的需求。
研究设计与样本
- 回顾性研究,查询机构数据库连续纳入2009年至2015年期间行Ivor Lewis食管胃切除术并使用STS食管胃吻合技术的278例患者,重点评估吻合口并发症。
主要发现
- 行STS食管胃吻合的患者共发生8例(2.9%)吻合口漏,其中3例为I/II级漏且无需干预。
- 良性病变行食管切除术后吻合口漏率为6.3%(2/32),其中2例漏均发生于因终末期贲门失弛缓症手术的8例患者中(25%);恶性病变行食管切除术后吻合口漏率为2.4%(6/246),P=0.22。
- 14例(5.0%)患者因吻合口狭窄需要扩张,中位扩张次数为2次。
- 这些患者出院后仅11.1%需要补充空肠造瘘喂养。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Anastomotic complications represent a significant source of morbidity and occasionally mortality after esophagectomy. Since 2009, we have used a novel "side-to-side: staple line-on-staple line" (STS) technique for intrathoracic esophagogastric anastomoses, designed to create a wide-diameter esophagogastric anastomosis while preserving stomach conduit blood supply. In this study, we describe the technique and review outcomes of our institution's initial 6-year experience. METHODS: An institutional database query identified 278 consecutive patients who underwent Ivor Lewis esophagogastrectomy using an STS esophagogastric anastomotic technique from 2009 through 2015. A retrospective review was conducted to assess outcomes with a focus on anastomotic complications. RESULTS: There were a total of 8 (2.9%) anastomotic leaks in patients who underwent STS esophagogastric anastomosis, 3 of which were grade I/II leaks and required no intervention. There was a leak rate of 6.3% (2 of 32) after esophagectomy for benign conditions (both leaks occurring in 8 total patients (25%) who received surgery for end-stage achalasia) compared with a 2.4% leak rate (6 of 246) in whom esophagectomy was performed for malignancy (P = .22). Fourteen patients (5.0%) required a median of 2 dilatations for anastomotic stricture after STS anastomosis. Supplemental jejunostomy feedings were required in only 11.1% of these patients after hospital discharge. CONCLUSIONS: We believe this novel STS technique provides excellent results with respect to the incidence of intrathoracic esophagogastric anastomotic leak and stricture after esophagectomy. Additionally this technique has significantly reduced the need for enteral feeding after hospital discharge.
引用
- Kesler KA, Ramchandani NK, Jalal SI, et al. Outcomes of a novel intrathoracic esophagogastric anastomotic technique. J Thorac Cardiovasc Surg. 2018. PMID: 30033105. doi:10.1016/j.jtcvs.2018.05.088
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。