文献速递心外重症与机械循环支持

术后心房颤动与左心室辅助装置置入后并发症发生率和资源利用增加相关

Postoperative atrial fibrillation is associated with increased morbidity and resource utilization after left ventricular assist device placement.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-04-18

本研究基于区域数据库2009至2017年1064例连续流左心室辅助装置置入患者,其中无房颤史689例按术后房颤分层分析。新发术后房颤发生率为17.6%,风险调整后与主要并发症、延长通气、非计划右心室辅助装置及资源利用增加相关,但与手术死亡或卒中无关联。

要点

  • 无房颤史患者左心室辅助装置置入后新发术后房颤发生率为17.6%。
  • 风险调整后术后房颤与主要并发症(OR 2.5,P=.0004)和延长通气(OR 2.7,P<.0001)相关。
  • 术后房颤与出院至机构(OR 2.2,P=.007)、额外4.9个术后住院日(P=.02)和重症监护室88小时(P=.01)相关。

核心结论

  • 术后房颤与主要并发症增加相关,可能源于右心衰竭恶化导致肾功能衰竭和非计划右心室辅助装置置入。
  • 术后房颤患者的重症监护室和住院时间更长,且更频繁地出院至机构。

研究设计与样本

  • 从区域数据库提取2009至2017年所有接受连续流左心室辅助装置置入的患者记录(n=1064)。
  • 无房颤史患者(n=689)按术后房颤分层进行单变量分析,并用多变量回归模型计算风险调整后关联。

主要发现

  • 新发术后房颤发生率为17.6%,发生术后房颤的患者年龄更大,且更可能伴有中度/重度二尖瓣反流、卒中史和同期三尖瓣手术。
  • 风险调整后,术后房颤与手术死亡或卒中无关联,但与主要并发症(OR 2.5,P=.0004)、延长通气(OR 2.7,P<.0001)、非计划右心室辅助装置(OR 2.9,P=.01)相关,肾功能衰竭呈趋势(OR 2.0,P=.06)。
  • 风险调整后,术后房颤与出院至机构(OR 2.2,P=.007)、额外4.9个术后住院日(P=.02)和重症监护室88小时(P=.01)相关。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Postoperative atrial fibrillation (POAF) is a known risk factor for morbidity and mortality after cardiac surgery but has not been investigated in the left ventricular assist device (LVAD) population. We hypothesize that POAF will increase morbidity and resource utilization after LVAD placement. METHODS: Records were extracted for all patients in a regional database who underwent continuous-flow LVAD placement (n = 1064, 2009-2017). Patients without a history of atrial fibrillation (n = 689) were stratified by POAF for univariate analysis. Multivariable regression models calculated the risk-adjusted association of arrhythmias on outcomes and resource utilization. RESULTS: The incidence of new-onset POAF was 17.6%, and patients who developed POAF were older and more likely to have moderate/severe mitral regurgitation, a history of stroke, and concomitant tricuspid surgery. After risk adjustment, POAF was not associated with operative mortality or stroke but was associated with major morbidity (odds ratio [OR] 2.5 P = .0004), prolonged ventilation (OR 2.7, P < .0001), unplanned right ventricular assist device (OR 2.9, P = .01), and a trend toward renal failure (OR 2.0, P = .06). In addition, POAF was associated with greater risk-adjusted resource utilization, including discharge to a facility (OR 2.2, P = .007), an additional 4.9 postoperative days (P = .02), and 88 hours in the intensive care unit (P = .01). CONCLUSIONS: POAF was associated with increased major morbidity, possibly from worsening right heart failure leading to increased renal failure and unplanned right ventricular assist device placement. This led to patients with POAF having longer intensive care unit and hospital stays and more frequent discharges to a facility.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Hawkins RB, Mehaffey JH, Guo A, et al. Postoperative atrial fibrillation is associated with increased morbidity and resource utilization after left ventricular assist device placement. J Thorac Cardiovasc Surg. 2018. PMID: 29801690. doi:10.1016/j.jtcvs.2018.03.169

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。