本研究在东北大学医院纳入2011至2017年间植入连续流左心室辅助装置的41例患者,用「vWF大分子多聚体指数」定量评估获得性血管性血友病综合征的血液学严重程度。随访中位591天,12例(29%)发生消化道出血,出血者该指数显著低于未出血者(25.0±10.3% vs 37.5±17.8%,P=0.008),且所有出血者该指数均低于40%。

要点

  • 41例连续流LVAD患者中12例(29%)随访期间发生消化道出血。
  • 出血者vWF大分子多聚体指数25.0±10.3%,低于未出血者的37.5±17.8%(P=0.008)。
  • 所有发生消化道出血的患者vWF大分子多聚体指数均低于40%。

核心结论

  • 发生消化道出血的患者vWF大分子多聚体丢失更严重,vWF大分子多聚体指数可能提示LVAD植入后消化道出血的风险。

研究设计与样本

  • 研究纳入2011至2017年在东北大学医院接受连续流左心室辅助装置治疗的41例患者。
  • 采用「vWF大分子多聚体指数」定量评估vWF大分子多聚体,该指数定义为患者来源的大多聚体占总vWF的比例与正常对照相应比例之比。
  • 每次检测时与正常对照同步分析,将vWF大分子多聚体量表示为正常对照值的百分比。

主要发现

  • 随访期中位591天,12例(29%)患者发生消化道出血事件。
  • 消化道出血患者vWF大分子多聚体指数为25.0±10.3%,无消化道出血患者为37.5±17.8%,前者显著低于后者(P=0.008)。
  • 所有发生消化道出血的患者vWF大分子多聚体指数均低于40%。

关键数值与推荐

  • vWF大分子多聚体指数低于40%见于所有发生消化道出血的患者。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Acquired von Willebrand syndrome, characterized by the reduction in von Willebrand factor (vWF) large multimers, has recently been considered as one of the causes of gastrointestinal bleeding (GIB). It remains unclear whether its haematological severity is linked with susceptibility to bleeding because the definition of the haematological severity of acquired von Willebrand syndrome has not been precisely determined. This study sought to establish a quantitative methodology to assess the haematological severity of acquired von Willebrand syndrome and to define the threshold for occurrence of GIB in patients implanted with left ventricular assist devices (LVADs). METHODS: In total, 41 patients treated with continuous-flow LVAD implanted between 2011 and 2017 at Tohoku University Hospital were investigated. vWF large multimers were quantitatively evaluated using the 'vWF large multimer index' defined as the ratio of a large multimer proportion in total vWF derived from a patient to that from a normal control. Using this index, the amount of vWF large multimers was expressed as a percentage of its normal control value obtained with a simultaneous analysis of each time measurement. RESULTS: Twelve (29%) patients developed GIB events during follow-up periods (median 591 days) after an LVAD implantation. The vWF large multimer index in patients with GIB was significantly lower than that in those without GIB (25.0 ± 10.3% vs 37.5 ± 17.8%, P = 0.008). Most importantly, all patients experiencing GIB exhibited a vWF large multimer index below 40%. CONCLUSIONS: Patients with GIB exhibited a more severe loss of vWF large multimers. The vWF large multimer index may dictate the risk of GIB after an LVAD implantation. CLINICAL TRIAL REGISTRATION NUMBER: UMIN000018135.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Sakatsume K, Saito K, Akiyama M, et al. Association between the severity of acquired von Willebrand syndrome and gastrointestinal bleeding after continuous-flow left ventricular assist device implantation. Eur J Cardiothorac Surg. 2018. PMID: 29741685. doi:10.1093/ejcts/ezy172