文献速递瓣膜外科

清醒与麻醉绵羊的三尖瓣动力学与三维几何

Tricuspid valvular dynamics and 3-dimensional geometry in awake and anesthetized sheep.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-04-21

研究在6只成年绵羊三尖瓣环周围植入超声测距晶体,比较清醒与麻醉状态下的三尖瓣复合体三维几何与动力学。麻醉未改变三尖瓣环或瓣下三维几何,但降低右心室收缩及三尖瓣环动力学,三尖瓣环面积收缩和环周收缩均下降。

要点

  • 麻醉下三尖瓣环面积收缩由16.4%降至11.2%,环周收缩由8.1%降至5.4%。
  • 三尖瓣环高度及乳头肌尖端至瓣环平面最小距离在麻醉前后无差异。
  • 麻醉下右心室前壁和侧壁局部收缩减弱,后壁保持不变。

核心结论

  • 全身麻醉未改变三尖瓣环或瓣下三维几何,但降低右心室收缩及三尖瓣环动力学。

研究设计与样本

  • 6只成年绵羊(50 ± 8 kg)在体外循环心脏跳动下植入6枚三尖瓣环超声测距晶体、乳头肌及右心室壁晶体和双心室压力传感器,恢复7天后分别于清醒和麻醉状态记录血流动力学与超声测距数据。

主要发现

  • 血流动力学参数两组间无差异。
  • 三尖瓣环面积收缩麻醉组较清醒组降低(16.4% ± 4.2% vs 11.2% ± 3.2%,P = .047)。
  • 三尖瓣环周长收缩麻醉组较清醒组降低(8.1% ± 2.2% vs 5.4% ± 1.7%,P = .050),主要因间隔瓣环收缩降低(10.5% ± 2.9% vs 7.5% ± 3.5%,P = .019)。
  • 右心室前壁(16.3% ± 3.1% vs 12.3% ± 2.2%,P = .027)和侧壁(14.9% ± 1.3% vs 11.5% ± 2.8%,P = .016)局部收缩在麻醉下减弱,后壁无变化。
  • 三尖瓣环高度及前、后、间隔乳头肌尖端至瓣环平面最小距离麻醉前后无差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Clinical and experimental tricuspid valve physiology data are derived predominantly from anesthetized subjects, but normal tricuspid valve geometry and dynamics may be altered by general anesthesia and mechanical ventilation. We set out to investigate 3-dimensional geometry and dynamics of the tricuspid valve complex in awake and anesthetized sheep. METHODS: While on cardiopulmonary bypass and with the heart beating, 6 adult sheep (50 ± 8 kg) underwent implantation of 6 sonomicrometry crystals around the tricuspid annulus. One crystal was implanted on the anterior, posterior, and septal papillary muscle tips, 4 on the right ventricular free wall and 1 on its apex. Pressure transducers were placed in both ventricles. Sonomicrometry and pressure transducer cables were externalized to subcutaneous buttons. After 7 days of recovery, hemodynamic and sonomicrometry data were recorded with animals awake and anesthetized. RESULTS: Hemodynamic parameters did not differ between groups. Tricuspid annular area contraction decreased with anesthesia (16.4% ± 4.2% vs 11.2% ± 3.2%, P = .047) as did tricuspid annular perimeter contraction (8.1% ± 2.2% vs 5.4% ± 1.7%, P = .050), predominantly due to reduced contraction of the septal annulus (10.5% ± 2.9% vs 7.5% ± 3.5%, P = .019). Tricuspid annular height did not differ between groups. Minimal distance from anterior, posterior, and septal papillary muscle tips to the annular plane did not change with anesthesia. Regional right ventricle free wall contraction was depressed under anesthesia in anterior (16.3% ± 3.1% vs 12.3% ± 2.2%, P = .027) and lateral (14.9% ± 1.3% vs 11.5% ± 2.8%, P = .016) segments, whereas the posterior remained unchanged. CONCLUSIONS: General anesthesia did not alter tricuspid annular or subvalvular 3-dimensional geometry but reduced right ventricular contraction and tricuspid annular dynamics.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Jazwiec T, Malinowski M, Proudfoot AG, et al. Tricuspid valvular dynamics and 3-dimensional geometry in awake and anesthetized sheep. J Thorac Cardiovasc Surg. 2018. PMID: 29804662. doi:10.1016/j.jtcvs.2018.04.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。