倾向性匹配分析:侧壁钳与吻合辅助装置在孤立性冠状动脉旁路移植术中的比较
基于日本成人心血管外科数据库(2013—2016年)回顾性分析孤立性非体外循环冠状动脉旁路移植术患者,按倾向性评分1:1匹配后侧壁钳组与吻合辅助装置组各7348例。两组30天死亡率和卒中率无显著差异;侧壁钳组短暂性脑缺血发作/可逆性缺血性神经功能缺陷/谵妄更多见,装置组新发心房颤动和延长通气更多见。
要点
- 匹配后侧壁钳组与装置组30天死亡率均为0.8%,卒中率均为1.4%,无显著差异。
- 侧壁钳组短暂性脑缺血发作/可逆性缺血性神经功能缺陷/谵妄发生率高于装置组(1.3% vs 0.9%,P=0.020)。
- 装置组新发心房颤动(12.8% vs 11.0%,P<0.001)和延长通气(2.9% vs 2.0%,P<0.001)发生率高于侧壁钳组。
核心结论
- 作者认为,吻合辅助装置在短暂性神经系统并发症方面部分提供了更好的结果,但本研究未观察到总体获益。
研究设计与样本
- 回顾性分析日本成人心血管外科数据库(2013—2016年)中接受孤立性非体外循环冠状动脉旁路移植术的患者。
- 按估计倾向性评分进行1:1匹配,吻合辅助装置组(Device组)n=14213,侧壁钳组(Side-clamp组)n=7374,匹配后各得7348例。
- 采用Pearson χ2检验比较早期结局和术后并发症详情,P<0.05为有统计学意义。
主要发现
- 30天死亡率:侧壁钳组0.8% vs 装置组0.8%,P=0.93。
- 卒中:侧壁钳组1.4% vs 装置组1.4%,P=0.46。
- 短暂性脑缺血发作/可逆性缺血性神经功能缺陷/谵妄:侧壁钳组1.3% vs 装置组0.9%,P=0.020,侧壁钳组更常见。
- 新发心房颤动:侧壁钳组11.0% vs 装置组12.8%,P<0.001,装置组更常见。
- 延长通气:侧壁钳组2.0% vs 装置组2.9%,P<0.001,装置组更常见;重症监护室住院时间无差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文为回顾性分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The use of an anastomosis assist device during coronary artery bypass grafting (CABG) is considered less invasive for the ascending aorta than the use of a side-biting clamp (Side-clamp) and to possibly be associated with a lower incidence of postoperative stroke. However, this benefit has not yet been clearly demonstrated. This study was to evaluate whether the use of an anastomosis assist device will minimize the postoperative stroke and other complications in patients undergoing off-pump CABG in comparison with the use of the Side-clamp. METHODS: Patients undergoing isolated off-pump CABG were retrospectively reviewed using the Japan Adult Cardiovascular Surgery Database (2013-2016). We performed a one-to-one matched analysis based on the estimated propensity scores of those who underwent off-pump CABG with an anastomosis assist device (Device group, n = 14 213) or a side-biting clamp (Side-clamp group, n = 7374) and obtained 2 cohorts (n = 7348 each). We compared the early outcomes and the details of postoperative complications using the Pearson's χ2 test. P-values of <0.05 were considered to indicate statistical significance. RESULTS: No significant differences were observed in the rates of 30-day mortality (Side-clamp versus Device: 0.8% vs 0.8%, P = 0.93) or stroke (1.4% vs 1.4%, P = 0.46). Transient ischaemic attack/reversible ischaemic neurological deficit/delirium occurred more frequently in the Side-clamp group (1.3% vs 0.9%, P = 0.020), whereas new-onset atrial fibrillation (11.0% vs 12.8%, P < 0.001) and prolonged ventilation (2.0% vs 2.9%, P < 0.001) occurred more frequently in the Device group. There was no difference in the length of intensive care unit stay. CONCLUSIONS: The use of an anastomosis assist device partially provided better results with regard to the transient neurological complications; however, no overall benefit was observed in this study.
引用
- Saito A, Kumamaru H, Ono M, et al. Propensity-matched analysis of a side-clamp versus an anastomosis assist device in cases of isolated coronary artery bypass grafting. Eur J Cardiothorac Surg. 2018. PMID: 29726986. doi:10.1093/ejcts/ezy177
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。