文献速递冠心病外科

非体外循环技术降低术前肾功能衰竭患者择期冠状动脉旁路移植术后手术死亡率

Off-pump technique reduces surgical mortality after elective coronary artery bypass grafting in patients with preoperative renal failure.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-04-12

基于日本心血管外科数据库2013至2015年38051例慢性肾脏病行首次非急诊孤立冠状动脉旁路移植术患者,按估算肾小球滤过率分层比较非体外循环与体外循环技术,采用逆概率治疗加权分析。结果显示在估算肾小球滤过率低于60 mL/min/1.73 m²的中重度肾功能不全患者中,非体外循环技术显著降低手术死亡率,在估算肾小球滤过率低于30 mL/min/1.73 m²患者中还与术后新发透析发生率显著降低相关;轻度肾功能减退患者中未见显著风险降低。

要点

  • 中重度肾功能不全患者中,非体外循环冠状动脉旁路移植术与手术死亡率显著降低相关。
  • 估算肾小球滤过率低于30 mL/min/1.73 m²患者中,非体外循环技术还与新发透析发生率显著降低相关。
  • 轻度肾功能减退患者中,非体外循环技术对手术死亡率未见显著风险降低效应。

核心结论

  • 非体外循环技术显著降低术前中重度肾功能不全患者的手术死亡率。

研究设计与样本

  • 研究分析日本心血管外科数据库-成人部分2013至2015年38051例慢性肾脏病行首次非急诊孤立冠状动脉旁路移植术患者。
  • 患者按估算肾小球滤过率60至90、30至59、低于30 mL/min/1.73 m²及依赖血液透析分为4类,采用逆概率治疗加权比较各层内非体外循环与体外循环冠状动脉旁路移植术的临床结局。

主要发现

  • 总体23634例(62.1%)患者计划接受非体外循环冠状动脉旁路移植术。
  • 轻度肾功能减退(估算肾小球滤过率60-89 mL/min/1.73 m²)患者中,非体外循环冠状动脉旁路移植术对手术死亡率未见显著风险降低效应。
  • 中重度肾功能不全(估算肾小球滤过率低于60 mL/min/1.73 m²)患者中,非体外循环冠状动脉旁路移植术与手术死亡发生率显著降低相关:估算肾小球滤过率30-59 mL/min/1.73 m²组比值比0.66(95%置信区间0.51-0.84);估算肾小球滤过率低于30 mL/min/1.73 m²组比值比0.51(95%置信区间0.37-0.72);依赖血液透析组比值比0.68(95%置信区间0.51-0.90)。
  • 重度肾功能不全(估算肾小球滤过率低于30 mL/min/1.73 m²)患者中,非体外循环冠状动脉旁路移植术与新发透析发生率显著降低相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Most randomized controlled trials of off-pump versus on-pump coronary artery bypass grafting (CABG) have included limited numbers of patients with preoperative renal failure. This study was performed to evaluate the association between the clinical benefit of the off-pump technique and chronic kidney disease stage. METHODS: We analyzed 38,051 patients with chronic kidney disease who underwent primary nonemergent isolated CABG from 2013 to 2015 as reported in the Japan Cardiovascular Surgery Database-Adult section. These patients were stratified into 4 categories according to their estimated glomerular filtration rate (eGFR) of 60 to 90, 30 to 59, and <30 mL/min/1.73 m2, and hemodialysis-dependent. The clinical outcomes were compared between patients undergoing off-pump and on-pump CABG in each stratum using inverse probability of treatment weighting. RESULTS: In total, 23,634 (62.1%) patients were intended for off-pump CABG. In patients with mildly reduced renal function (eGFR 60-89 mL/min/1.73 m2), there was no significant risk reduction effect of off-pump CABG for surgical mortality. Conversely, in patients with moderate or severe renal disease (eGFR <60 mL/min/1.73 m2), off-pump CABG was associated with a significantly lower incidence of surgical death (odds ratio with 95% confidence interval: eGFR 30-59 mL/min/1.73 m2, 0.66 [0.51-0.84]; eGFR <30 mL/min/1.73 m2, 0.51 [0.37-0.72]; and hemodialysis-dependent, 0.68 [0.51-0.90]). In addition, in patients with severe renal disease (eGFR of <30), off-pump CABG was associated with a significantly lower incidence of de novo dialysis. CONCLUSIONS: The off-pump technique significantly reduced surgical mortality in patients with moderate or severe preoperative renal dysfunction.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Ueki C, Miyata H, Motomura N, et al. Off-pump technique reduces surgical mortality after elective coronary artery bypass grafting in patients with preoperative renal failure. J Thorac Cardiovasc Surg. 2018. PMID: 29753505. doi:10.1016/j.jtcvs.2018.03.145

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。