文献速递瓣膜外科主动脉外科

二叶式或三叶式主动脉瓣患者行主动脉瓣及升主动脉置换术后主动脉根部不随时间扩张

The aortic root does not dilate over time after replacement of the aortic valve and ascending aorta in patients with bicuspid or tricuspid aortic valves.
PubMed 文献 · J Thorac Cardiovasc Surg · 2018-03-13

单中心回顾1990至2010年406例(二叶式269例、三叶式137例)行主动脉瓣及升主动脉置换术患者,随访影像显示二叶式组主动脉根部直径年增长0.654毫米(95%CI 0.291-1.016,P<.001),与三叶式组相似(P=.92);两组主动脉再手术累积发生率无差异(P=.14)。作者认为术中根部未扩张者远期扩大风险极小,无需预防性根部置换。

要点

  • 二叶式组主动脉根部直径年增长0.654毫米(95%CI 0.291-1.016,P<.001),与三叶式组相似(P=.92)。
  • 随访期间18例再手术,89%因生物瓣衰败,仅1例因主动脉瘤样病变再手术。
  • 二叶式与三叶式组主动脉再手术累积发生率无差异(P=.14)。

核心结论

  • 主动脉瓣及升主动脉置换术后中期影像显示,若术中主动脉根部未扩张,随时间扩大的风险极小,无需在二叶式或三叶式主动脉瓣患者中行预防性根部置换。

研究设计与样本

  • 单中心回顾性研究,纳入1990年至2010年行主动脉瓣及升主动脉置换术的406例患者(二叶式269例、三叶式137例)。
  • 排除主动脉夹层、心内膜炎、既往主动脉手术或马方综合征患者。
  • 回顾所有可获得的随访影像。

主要发现

  • 平均影像随访5.5(±5.3)年,66.5%的患者在索引术后至少有一次主动脉根部测量。
  • 两组基线主动脉直径相当。
  • 二叶式组主动脉根部直径随时间以临床可忽略的速率增加(每年0.654毫米;95%CI 0.291-1.016;P<.001),与三叶式组相似(P=.92)。
  • 平均临床随访8.1(±5.4)年,18例再手术,其中89%因生物瓣衰败。
  • 仅1例以主动脉瘤样病变为主要指征再手术,发生于索引术后22年;二叶式与三叶式组主动脉再手术累积发生率无差异(P=.14)。

临床怎么用

  • 作者认为,若术中主动脉根部未扩张,二叶式或三叶式主动脉瓣患者无需预防性根部置换。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Whether the aortopathy associated with bicuspid aortic valve (BAV) disease occurs secondary to genetic or hemodynamic factors remains controversial. In this article we describe the natural history of the aortic root in patients with bicuspid versus tricuspid aortic valves (TAVs) after replacement of the aortic valve and ascending aorta. METHODS: From 1990 to 2010, 406 patients (269 BAV, 137 TAV) underwent aortic valve and ascending aorta replacement at a single institution. Patients with aortic dissection, endocarditis, previous aortic surgery, or Marfan syndrome were excluded. All available follow-up imaging was reviewed. RESULTS: Mean imaging follow-up was 5.5 (±5.3) years. Of all patients, 66.5% had at least 1 aortic root measurement after the index operation. Baseline aortic diameter was comparable between groups. In patients with BAV, aortic root diameter increased at a clinically negligible rate over time (0.654 mm per year; 95% confidence interval, 0.291-1.016; P < .001), similar to patients with TAV (P = .92). Mean clinical follow-up was 8.1 (±5.4) years. During follow-up, 18 patients underwent reoperation, 89% for a degenerated bioprosthetic aortic valve. Only 1 patient underwent reoperation for a primary indication of aortic aneurysmal disease, 22 years after the index operation. There were no differences in cumulative incidence rates of aortic reoperation (P = .14) between patients with BAV and TAV. CONCLUSIONS: Mid-term imaging after aortic valve and ascending aorta replacement indicates that if the aortic root is not dilated at the time of surgery, the risk of enlargement over time is minimal, negating the need for prophylactic root replacement in patients with BAV or TAV.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Hui SK, Fan CS, Christie S, et al. The aortic root does not dilate over time after replacement of the aortic valve and ascending aorta in patients with bicuspid or tricuspid aortic valves. J Thorac Cardiovasc Surg. 2018. PMID: 29656818. doi:10.1016/j.jtcvs.2018.02.094

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。