武士插管法(直接真腔插管)用于急性Stanford A型主动脉夹层
该回顾性研究比较了2011年4月至2017年4月期间在Kitasato大学医院因急性Stanford A型主动脉夹层手术的100例患者中,仅使用武士插管法(S组,61例)与其他插管方式(O组,39例)的早期结局。S组真腔插管全部成功,无插管相关并发症,而O组出现3例插管相关并发症。两组早期死亡率或卒中率无显著差异,随访期间生存率、免于主动脉相关死亡或主动脉事件率亦无统计学显著差异。作者认为武士插管法是一种简单、安全且合理的选择。
要点
- 武士插管法在全部61例S组患者中成功实现真腔插管。
- O组出现3例插管相关并发症,S组无插管相关并发症。
- 两组早期死亡率及卒中率无显著差异。
核心结论
- 武士插管法用于急性Stanford A型主动脉夹层手术的早期结局良好,死亡率和卒中率可接受,且无插管相关并发症。
- 作者认为武士插管法是一种简单、安全且合理的体外循环插管选择。
研究设计与样本
- 回顾性分析2011年4月至2017年4月在Kitasato大学医院因急性Stanford A型主动脉夹层手术的100例患者,仅用武士插管法者61例(S组),其他插管方式者39例(O组)。
主要发现
- S组真腔插管全部成功,O组出现3例插管相关并发症。
- S组30天死亡3例(5%),院内死亡4例(7%);O组30天死亡3例(8%),院内死亡6例(15%)。
- 每组各有4例(S组7%,O组10%)发生致残性或致命性卒中。
- 两组早期死亡率或卒中率无显著差异,随访期间生存率、免于主动脉相关死亡或免于主动脉事件率亦无统计学显著差异。
临床怎么用
- 作者认为武士插管法可作为急性Stanford A型主动脉夹层手术中体外循环的一种简单、安全且合理的选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: In this study, we investigated early outcomes of patients who underwent surgical aortic repair for acute Stanford Type A aortic dissection at the Kitasato University Hospital and compared the results of Samurai cannulation (direct true-lumen cannulation) with other cannulation options. METHODS: Inpatient and outpatient records were retrospectively reviewed. RESULTS: Among the 100 patients who were operated on for acute Type A aortic dissection between April 2011 and April 2017, sole Samurai cannulation was used in 61 patients (Group S) and other cannulation options were used in the remaining 39 patients (Group O). No significant difference was observed in preoperative demographics between the groups. True-lumen cannulation was successful in all Group S patients, whereas 3 cannulation-related complications were observed in Group O patients. In Group S, the 30-day and in-hospital mortality occurred in 3 (5%) and 4 (7%) patients, respectively, and in Group O, these occurred in 3 (8%), and 6 (15%) patients, respectively. Four patients in each group (7% and 10%) experienced disabling or fatal strokes. Early mortality or stroke rate between the groups were not significantly different. During follow-up, there was no statistically significant difference between the groups in terms of survival, freedom from aorta-related death or freedom from aortic events. CONCLUSIONS: Early outcomes of the initial series of surgery for Stanford Type A aortic dissection with Samurai cannulation was favourable with acceptable mortality and stroke rates without cannulation-related complications. Samurai cannulation represents an easy, safe and reasonable option for cardiopulmonary bypass in surgery for acute Stanford Type A aortic dissection.
引用
- Kitamura T, Torii S, Kobayashi K, et al. Samurai cannulation (direct true-lumen cannulation) for acute Stanford Type A aortic dissection. Eur J Cardiothorac Surg. 2018. PMID: 29490035. doi:10.1093/ejcts/ezy066
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。