经心尖导管主动脉瓣植入术后后乳头肌断裂
本文报道一例83岁症状性重度主动脉瓣狭窄女性患者,经心尖导管主动脉瓣植入术后在重症监护室出现血流动力学不稳定,经食管超声心动图发现后乳头肌断裂导致重度二尖瓣反流伴A2、A3脱垂,行二尖瓣置换术修复。术前经食管超声心动图显示右心室扩张致左心室后移位,CT显示导丝从左心室心尖至主动脉瓣的插入角度为95.6°且导丝通过主动脉瓣角度较锐。
要点
- 经心尖导管主动脉瓣植入术后出现血流动力学不稳定需警惕心脏结构损伤。
- 经食管超声心动图可发现后乳头肌断裂导致的重度二尖瓣反流。
- 右心室扩张致左心室后移位及导丝角度较锐时需小心操作以避免结构损伤。
核心结论
- 经心尖导管主动脉瓣植入术后可发生后乳头肌断裂导致重度二尖瓣反流,需行二尖瓣置换术修复。
- 在右心室扩张致左心室后移位、导丝插入角度为95.6°且通过主动脉瓣角度较锐的情况下,需小心进行导管操作以预防心脏结构损伤,后乳头肌尤其关键。
研究设计与样本
- 病例报告:一例83岁症状性重度主动脉瓣狭窄女性患者接受经心尖导管主动脉瓣植入术。
主要发现
- 术中经食管超声心动图显示轻度二尖瓣反流,无心脏结构损伤。
- 在重症监护室患者逐渐出现血流动力学不稳定,经食管超声心动图显示后乳头肌断裂导致重度二尖瓣反流伴A2和A3脱垂。
- 行二尖瓣置换术修复二尖瓣反流。
- 术前经食管超声心动图显示右心室扩张致左心室后移位。
- CT显示导丝从左心室心尖至主动脉瓣的插入角度为95.6°,导丝通过主动脉瓣角度较锐。
关键数值与推荐
- 导丝从左心室心尖至主动脉瓣的插入角度为95.6°。
临床怎么用
- 作者认为,在右心室扩张致左心室后移位、导丝插入角度为95.6°且通过主动脉瓣角度较锐的情况下,需小心进行导管操作以预防心脏结构损伤,后乳头肌尤其关键。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Transapical transcatheter aortic valve implantation is a well-established alternative in patients at a high risk for conventional aortic valve replacement. We performed transapical transcatheter aortic valve implantation on an 83-year-old woman with symptomatic severe aortic stenosis. Intraoperative transoesophageal echocardiography (TOE) after transcatheter aortic valve implantation showed mild mitral regurgitation without intracardiac structural injury. In the intensive care unit, the patient gradually had haemodynamic instability; TOE revealed severe mitral regurgitation with A2 and A3 prolapse due to rupture of the posterior papillary muscle. To repair the mitral regurgitation, mitral valve replacement was performed. Preoperative TOE revealed posterior displacement of the left ventricle due to right ventricular dilatation. Computed tomography showed the insertion angle of the guidewire from the left ventricular apex to the aortic valve as 95.6° and a relatively sharp angle of guidewire through the aortic valve. In such a case, it is necessary to carefully perform the catheter procedures to prevent intracardiac structure injury; posterior papillary muscle is particularly crucial.
引用
- Komagamine M, Furukawa N, Gummert J, et al. Posterior papillary muscle rupture after transapical transcatheter aortic valve implantation. Eur J Cardiothorac Surg. 2018. PMID: 29514193. doi:10.1093/ejcts/ezy103
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。