冰冻象鼻支架植入术后下游主动脉真腔与假腔直径变化
本研究评估65例急性(31例)与慢性(34例)胸主动脉夹层患者行全主动脉弓置换联合冰冻象鼻支架术后的早期与中期结局及下游主动脉重塑。随访期间各节段均见真腔扩张与假腔缩小,慢性夹层支架段最明显;下游再干预率28%,结论认为该技术临床结局良好并有效诱导重塑,但需进一步研究长期结局。
要点
- 65例胸主动脉夹层患者行冰冻象鼻支架术,住院死亡率6%,未观察到症状性脊髓损伤。
- 平均随访12±12个月,各节段均见真腔扩张、假腔缩小,慢性夹层支架段最显著。
- 下游主动脉再干预率28%,平均再干预时间394±385天,作者认为需进一步研究长期结局。
核心结论
- 冰冻象鼻支架技术在该复杂队列中临床结局良好,并在急性与慢性胸主动脉夹层中有效诱导下游主动脉节段重塑。
- 下游节段二次干预需求仍然 substantial,主要取决于基础疾病进程的范围。
- 作者认为需进一步研究评估该方法的长期结局。
研究设计与样本
- 单中心4年期间连续65例(男48例,年龄61±12岁)因急性(n=31)与慢性(n=34)胸主动脉夹层行全主动脉弓置换联合冰冻象鼻支架术的患者。
- 评估支架段(L1)、胸腹过渡段(L2)与腹腔干水平(L3)三个水平的真腔与假腔直径变化。
主要发现
- 56%患者既往已接受主动脉或心脏手术;住院死亡率6%;本系列未观察到症状性脊髓损伤。
- 平均随访12±12个月,晚期死亡6%,下游主动脉再干预28%,平均再干预时间394±385天。
- 所有节段均测得真腔扩张与假腔缩小,各水平均观察到该效应;慢性夹层支架段最显著:真腔直径从术前15±17 mm增至2年后28±2 mm(P=0.001),假腔直径从术前40±11 mm降至32±17 mm(P=0.026)。
关键数值与推荐
- 慢性夹层支架段真腔直径术前15±17 mm vs 术后2年28±2 mm(P=0.001)。
- 慢性夹层支架段假腔直径术前40±11 mm vs 术后2年32±17 mm(P=0.026)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 作者指出需进一步研究评估该方法的长期结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate early and mid-term clinical outcomes and to assess the potential of the frozen elephant trunk technique to induce remodelling of downstream aortic segments in acute and chronic thoracic aortic dissections. METHODS: Over a 4-year period, 65 patients (48 men, aged 61 ± 12 years) underwent total aortic arch replacement using the frozen elephant trunk technique for acute (n = 31) and chronic (n = 34) thoracic aortic dissections at our institution. We assessed diameter changes at 3 levels: the L1 segment at the stent graft level; the L2 segment at the thoraco-abdominal transition level and the L3 segment at the coeliac trunk level. True-lumen (TL) and false-lumen (FL) diameter changes were assessed at each level. RESULTS: Fifty-six percent of patients had already undergone previous aortic or cardiac surgery. In-hospital mortality was 6%. Symptomatic spinal cord injury was not observed in this series. During a mean follow-up of 12 ± 12 months, late death was observed in 6% of patients. Aortic reinterventions in downstream aortic segments were performed in 28% at a mean of 394 ± 385 days. TL expansion and FL shrinkage were measured in all segments and were observed at each level. This effect was the most pronounced at the level of the stent graft in patients with chronic aortic dissection, TL diameter increased from 15 ± 17 mm before surgery to 28 ± 2 mm (P = 0.001) after 2 years, and the FL diameter decreased from 40 ± 11 mm before surgery to 32 ± 17 mm (P = 0.026). CONCLUSIONS: The frozen elephant trunk technique is associated with an excellent clinical outcome in a complex cohort of patients, and also effectively induces remodelling in downstream aortic segments in acute and chronic thoracic aortic dissections. The need for secondary interventions in downstream segments, which mainly depends on the extent of the underlying disease process, remains substantial. Further studies are required to assess the long-term outcome of this approach.
引用
- Berger T, Kreibich M, Morlock J, et al. True-lumen and false-lumen diameter changes in the downstream aorta after frozen elephant trunk implantation. Eur J Cardiothorac Surg. 2018. PMID: 29471419. doi:10.1093/ejcts/ezy031