文献速递主动脉外科

预测慢性DeBakey III型主动脉夹层腔内修复术后远端主动脉重塑

Predicting Distal Aortic Remodeling After Endovascular Repair for Chronic DeBakey III Aortic Dissection.
PubMed 文献 · Ann Thorac Surg · 2018-01-31

本研究基于48例2005至2015年接受TEVAR的慢性DeBakey III型主动脉夹层患者,分析术前术后CT血管造影三维重建,探讨与主动脉良性重塑相关的因素。多因素分析显示,真腔供血的内脏血管少于两支是全血栓形成的负向预测因子,腹腔干上方2cm处最大直径是全血栓形成的负向预测因子,术前最大整体直径和破口位于大弯侧是术后1年内降主动脉最大整体直径未回缩的显著正向预测因子。结论认为TEVAR在慢性夹层中可行但受复杂解剖限制,假腔供血内脏血管数量增加、术前主动脉尺寸较大及破口位于大弯侧与较差的重塑相关。

要点

  • 真腔供血的内脏血管少于两支是全血栓形成的负向预测因子(OR 0.01,95%CI <0.01至0.84,p=0.04)。
  • 腹腔干上方2cm处最大直径是全血栓形成的负向预测因子(OR 0.75,95%CI 0.57至0.99,p=0.05)。
  • 术前最大整体直径(OR 1.19,95%CI 1.02至1.29,p=0.03)和破口位于大弯侧(OR 18.1,95%CI 1.3至243,p=0.03)是术后1年内降主动脉最大整体直径未回缩的显著正向预测因子。

核心结论

  • TEVAR在慢性夹层中可行,但受复杂夹层相关解剖限制。
  • 假腔供血内脏血管数量增加、术前主动脉最大尺寸较大及原发破口位于大弯侧与较差的重塑相关。

研究设计与样本

  • 回顾性分析48例2005至2015年接受TEVAR的慢性DeBakey III型主动脉夹层患者。
  • 对计算机断层扫描血管造影进行三维重建(M2S,West Lebanon,NH),在四个时间点获取术前和术后测量值。
  • 使用Wilcoxon秩和检验和Fisher精确检验进行单变量分析,并进行多变量逻辑回归。

主要发现

  • 在多变量逻辑模型中,真腔供血的内脏血管少于两支是全血栓形成的负向预测因子(OR 0.01,95%CI <0.01至0.84,p=0.04)。
  • 在预测第3和第4区全血栓形成的逻辑模型中,腹腔干上方2cm处最大直径是显著的负向预测因子(OR 0.75,95%CI 0.57至0.99,p=0.05)。
  • 在预测TEVAR术后1年内降主动脉最大整体直径未回缩的模型中,术前最大整体直径(OR 1.19,95%CI 1.02至1.29,p=0.03)和破口位于大弯侧(OR 18.1,95%CI 1.3至243,p=0.03)是显著的正向预测因子。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Chronic DeBakey III aortic dissection is typically managed with open aortic reconstruction. Thoracic endovascular aortic grafting (TEVAR) has been attempted in patients with chronic DeBakey III with improved outcomes over medical management, however with frequent failures. This study investigates factors associated with positive aortic remodeling from a large aortic center. METHODS: Three-dimensional reconstructions (M2S, West Lebanon, NH) of computed tomography angiography scans of 48 patients who underwent TEVAR from 2005 to 2015 were analyzed. The dissection was characterized, and measurements were obtained from preoperative and postoperative scans at four time points. Standard univariate Wilcoxon rank sum and Fisher's exact tests were used to analyze continuous and ordinal/nominal data, respectively. Multivariable logistic regression was performed. RESULTS: In a multivariate logistic model, having fewer than two visceral vessels off the true lumen was a negative predictor of total thrombosis (odd ratio [OR] 0.01, 95% confidence interval [CI]: <0.01 to 0.84, p = 0.04). In a logistic model that predicted total thrombosis in zones 3 and 4, maximum diameter 2 cm above the celiac axis was a significant negative predictor (OR 0.75, 95% CI: 0.57 to 0.99, p = 0.05). In a model that predicted failure of the maximum overall diameter of the descending aorta to regress within 1 year after TEVAR, maximum overall diameter preoperatively (OR 1.19, 95% CI: 1.02 to 1.29, p = 0.03) and tear location on the greater curve (OR 18.1, 95% CI: 1.3 to 243, p = 0.03) were significant positive predictors. CONCLUSIONS: TEVAR is feasible in chronic dissection but is limited by complex dissection-related anatomy. Increasing number of visceral vessels off the false lumen, maximum preoperative aortic size, and location of the primary tear on the greater curve were associated with poorer remodeling.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Sultan I, Siki MA, Bavaria JE, et al. Predicting Distal Aortic Remodeling After Endovascular Repair for Chronic DeBakey III Aortic Dissection. Ann Thorac Surg. 2018. PMID: 29391144. doi:10.1016/j.athoracsur.2018.01.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。