微创入路快速释放主动脉瓣置换术的中期临床与超声心动图结局
该研究纳入143例经右上半胸骨切开行快速释放主动脉瓣置换术的患者,从2012年3月至2015年9月每年随访,累计随访275.2患者年,中位随访1.9年。早期全因死亡率为2.8%(n=4),1年生存率91.6±2.4%,3年生存率84.4±3.6%。术后12个月平均跨瓣压差10.3±3.8 mmHg,随访期间未出现新发高级别瓣周漏。作者认为快速释放瓣膜在微创入路中安全可行,是微创手术的相关选择。
要点
- 143例经右上半胸骨切开行快速释放主动脉瓣置换术,早期全因死亡率2.8%(n=4)。
- 1年生存率91.6±2.4%,3年生存率84.4±3.6%,中位随访1.9年。
- 术后12个月平均跨瓣压差10.3±3.8 mmHg,随访期间无新发高级别瓣周漏。
核心结论
- 作者认为快速释放主动脉瓣置换术可在微创入路中安全实施,并发症率低且血流动力学结果良好,快速释放瓣膜是微创手术的相关选择。
研究设计与样本
- 单臂研究,2012年3月至2015年9月共143例患者经右上半胸骨切开行快速释放主动脉瓣置换术,每年随访,术后12个月行超声心动图评估。
- 累计随访275.2患者年,中位随访1.9年。
主要发现
- 平均年龄76.4±6.2岁,平均logistic EuroSCORE为11.0±4.3%。
- 早期全因死亡率为2.8%(n=4),1年生存率91.6±2.4%,3年生存率84.4±3.6%。
- 术后12个月平均跨瓣压差为10.3±3.8 mmHg。
- 围术期高级别瓣周漏(主动脉瓣反流>1+)发生于2例(1.4%),随访期间未出现新发高级别瓣周漏。
临床怎么用
- 作者认为快速释放瓣膜是微创主动脉瓣手术的相关选择。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Transcatheter procedures have overtaken conventional operations in Germany. Considering that this is a highly competitive field, a rate of 25% for minimal access aortic valve replacement seems to be disappointingly low. One way to promote minimal access techniques is through the systematic use of rapid deployment valves. METHODS: A total of 143 patients underwent rapid deployment aortic valve replacement via upper right hemisternotomy between March 2012 and September 2015. All patients were followed up annually. Echocardiographic assessment of the valve was performed after 12 months. The cumulative follow-up time was 275.2 patient-years. The median follow-up time was 1.9 years. RESULTS: The mean age was 76.4 ± 6.2 years, and the mean logistic EuroSCORE was 11.0 ± 4.3%. Early all-cause mortality was 2.8% (n = 4). Actuarial survival after 1 year was 91.6 ± 2.4%, and after 3 years, it was 84.4 ± 3.6%. Mean transprosthetic gradient after 12 months was 10.3 ± 3.8 mmHg. New onset of higher grade paravalvular leakage did not occur during the follow-up period. Perioperatively, higher grade paravalvular leakage (aortic insufficiency >1+) occurred in 2 cases (1.4%) . CONCLUSIONS: Rapid deployment aortic valve replacement can be performed safely in a minimal access setting with low complication rates and good haemodynamic results. Therefore, rapid deployment valves are a relevant option in minimal access surgery.
引用
- Schlömicher M, Taghiyev Z, AlJabery Y, et al. Rapid deployment aortic valve replacement in a minimal access setting: intermediate clinical and echocardiographic outcomes. Eur J Cardiothorac Surg. 2018. PMID: 29420709. doi:10.1093/ejcts/ezy023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。