文献速递先天性心脏病外科

先天性心脏病手术中微型化小儿体外循环管路无血预充:与输血需求相关的独立预测因素及对术后并发症的影响

Asanguineous priming of miniaturized paediatric cardiopulmonary bypass circuits for congenital heart surgery: independent predictors associated with transfusion requirements and effects on postoperative morbidity.
PubMed 文献 · Eur J Cardiothorac Surg · 2018-01-01

回顾性分析579例体重≤15 kg、在2013年5月至2015年5月间接受先天性心脏病手术的患儿,采用微型化体外循环管路无血预充。避免输血的能力与体重相关:体重<3 kg患儿体外循环期间输血率为0.53(95%CI 0.37-0.69),体重>8 kg为0.14(95%CI 0.10-0.19);住院期间输血率分别为1.00(95%CI 0.90-1.00)和0.67(95%CI 0.60-0.73)。体重、术前血红蛋白浓度、体外循环时长和姑息手术与体外循环期间输血独立相关;输血(尤其体外循环期间输血)与更长的机械通气时间(HR 3.52,95%CI 2.66-4.65)和ICU停留时间(HR 2.52,95%CI 1.91-3.32)独立相关。

要点

  • 体重<3 kg患儿体外循环期间输血率为0.53(95%CI 0.37-0.69),体重>8 kg为0.14(95%CI 0.10-0.19)。
  • 体重、术前血红蛋白、体外循环时长和姑息手术与体外循环期间输血独立相关。
  • 体外循环期间输血与更长机械通气时间(HR 3.52,95%CI 2.66-4.65)和ICU停留时间(HR 2.52,95%CI 1.91-3.32)独立相关。

核心结论

  • 使用微型化体外循环管路时无血预充是可行的,可能有助于避免体外循环患者输血并减少输血需求及输血相关并发症。

研究设计与样本

  • 回顾性分析2013年5月至2015年5月两年期间所有体重≤15 kg的先天性心脏病手术患儿数据,共579例。

主要发现

  • 体重<3 kg患儿体外循环期间输血率为0.53(95%CI 0.37-0.69),体重>8 kg患儿为0.14(95%CI 0.10-0.19)。
  • 体重<3 kg患儿住院期间输血率为1.00(95%CI 0.90-1.00),体重>8 kg患儿为0.67(95%CI 0.60-0.73)。
  • 体重、术前血红蛋白浓度、体外循环时长和姑息手术与体外循环期间输血独立相关。
  • 输血(尤其体外循环期间输血)与更长机械通气时间(HR 3.52,95%CI 2.66-4.65)和ICU停留时间(HR 2.52,95%CI 1.91-3.32)独立相关。

临床怎么用

  • 本研究中心的做法是在临床常规中采用无血预充。
  • 作者认为无血预充使用微型化体外循环管路可行,可能有助于避免体外循环患者输血并减少输血需求及输血相关并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: In paediatric cardiac surgery, body weight-adjusted miniaturized cardiopulmonary bypass (CPB) circuits within a comprehensive blood-sparing approach can reduce transfusion requirements. Haemodilution resulting from mixing the patient's blood with a CPB crystalloid solution may be reduced to the extent that asanguineous priming becomes possible. Therefore, we adopted asanguineous priming in our clinical routine. Our goal was to report the effects of asanguineous priming on transfusion requirements, clinical features associated with transfusion and effects on in-hospital morbidity. METHODS: Data of all paediatric patients with body weights up to 15 kg treated within a 2-year period between May 2013 and May 2015 were retrospectively analysed. The incidence of transfusions was analysed and periprocedural haemoglobin concentrations were evaluated. Predictors associated with transfusion requirements, duration of ventilation or length of stay in the intensive care unit were evaluated by multivariable analyses. RESULTS: Data from 579 patients with body weights up to 15 kg were analysed. The ability to avoid transfusion depended on body weight: in patients <3 kg, the rate (95% confidence interval) of transfusion during CPB was 0.53 (0.37-0.69), and in patients >8 kg, the rate was 0.14 (0.10-0.19). The respective rates of transfusions throughout the hospital stay were 1.00 (0.90-1.00) and 0.67 (0.60-0.73). Body weight, preoperative haemoglobin concentration, duration of CPB and palliative surgery were independently associated with transfusion during CPB. Transfusion, particularly transfusion during CPB, was independently associated with longer mechanical ventilation time (hazard ratio 3.52, confidence interval 2.66-4.65) and length of stay in the intensive care unit (hazard ratio 2.52, confidence interval 1.91-3.32). CONCLUSIONS: Asanguineous priming is feasible using miniaturized CPB circuits. It may help to avoid blood transfusions in patients on CPB and reduce transfusion requirements and transfusion-related morbidity.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Boettcher W, Redlin M, Dehmel F, et al. Asanguineous priming of miniaturized paediatric cardiopulmonary bypass circuits for congenital heart surgery: independent predictors associated with transfusion requirements and effects on postoperative morbidity. Eur J Cardiothorac Surg. 2018. PMID: 29300861. doi:10.1093/ejcts/ezx479

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。