文献速递先天性心脏病外科

功能性单心室患者腔肺吻合术后腋动脉-静脉瘘的适应证与结果

Indications for and results of axillary arterio-venous fistula in patients with a functionally single ventricle after cavopulmonary anastomosis†.
PubMed 文献 · Eur J Cardiothorac Surg · 2019-01-01

本研究回顾2012至2017年20例双向腔肺连接术后患者接受腋动脉-静脉瘘手术,评估手术前后临床与血流动力学参数。术后平均动脉血氧饱和度从72.4±7.1%升至81.6±5.5%(P<0.001),出院时83.8±6.5%(P=0.002),上腔静脉血流速度及分钟容量增加,中期随访1至5年2例死于并存疾病,作者认为该术式可作为手术分期及过渡至Fontan和/或心脏移植的桥接。

要点

  • 腋动脉-静脉瘘术后平均动脉血氧饱和度从72.4±7.1%升至81.6±5.5%(P<0.001)。
  • 上腔静脉血流速度从21.1±8.3 cm/s增至28.8±14.9 cm/s(P<0.001)。
  • 中期随访1至5年2例死于并存疾病,1例3年内接受Fontan手术。

核心结论

  • 腋动脉-静脉瘘可作为此类患者手术分期的阶段及过渡至Fontan和/或心脏移植的桥接。

研究设计与样本

  • 回顾性分析2012至2017年本机构20例双向腔肺连接术后接受腋动脉-静脉瘘的患者,年龄21.1±8.7岁(中位20.5岁),双向腔肺连接至腋动脉-静脉瘘间隔13.9±7.2年,评估手术前后临床与血流动力学参数。

主要发现

  • 无院内死亡,手臂感觉异常持续1至7天。
  • 平均动脉血氧饱和度术前72.4±7.1% vs 术后81.6±5.5%(P<0.001),出院时83.8±6.5%(P=0.002,Wilcoxon配对检验)。
  • 血红蛋白、血细胞比容、McGoon指数及射血分数无显著变化。
  • 上腔静脉血流速度从21.1±8.3 cm/s增至28.8±14.9 cm/s(P<0.001),分钟容量从10.6±3.7 ml/s增至12.5±2.9 ml/s(P<0.001)。
  • 中期随访1至5年,2例死于并存疾病;术前17例NYHA心功能III级、3例IV级,术后9例II级、3例III级;1例3年内接受Fontan手术。

临床怎么用

  • 作者认为腋动脉-静脉瘘可作为此类患者手术分期的阶段及过渡至Fontan和/或心脏移植的桥接。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study aimed to investigate the indications for and the results of axillary arterio-venous fistula in patients with a functionally single ventricle at mid-term follow-up after bidirectional cavopulmonary connection. METHODS: From 2012 to 2017, 20 patients aged 21.1 ± 8.7 years (median 20.5) underwent axillary arterio-venous fistula after bidirectional cavopulmonary connection in our institution. The interval between bidirectional cavopulmonary connection and axillary arterio-venous fistula was 13.9 ± 7.2 years. The clinical and haemodynamic parameters of the patients were assessed before and after surgery. RESULTS: There was no in-hospital mortality. Paraesthesia of the arm persisted for 1-7 days. The mean arterial oxygen saturation increased from 72.4 ± 7.1% pre-surgery to 81.6 ± 5.5% (P < 0.001) after surgery, and was 83.8 ± 6.5% at discharge (P = 0.002 Wilcoxon matched pairs test). The haemoglobin, haematocrit, McGoon index and ejection fraction values did not change significantly. The speed and minute volume of the blood flow in the superior vena cava increased from from 21.1 ± 8.3 cm/s to 28.8 ± 14.9 cm/s (P < 0.001) and from 10.6 ± 3.7 ml/s to 12.5 ± 2.9 ml/s (P < 0.001), respectively. At the mid-term follow-up (1-5 years), 2 patients died from concomitant pathology. Stable improvement in the state and tolerance of physical activity was noted: before surgery, 17 patients were classified as New York Heart Association functional capacity (FC) III and 3 patients as FC IV; after surgery, 9 patients were FC II and 3 patients were FC III. One patient underwent a Fontan operation within 3 years. CONCLUSIONS: Axillary arterio-venous fistula can be used as the stage of surgical treatment and a bridge to Fontan and/or heart transplantation for this category of patients.