主动脉瘤与主动脉夹层中的主动脉延长:Tübingen主动脉病理解剖(TAIPAN)项目
该研究基于CT血管造影分析256例健康、102例扩张、38例动脉瘤、17例夹层前及166例A型主动脉夹层(TAD)主动脉的长度与直径。结果显示升主动脉延长在病变组更常见,结合直径与长度的评分可识别23.5%的夹层前患者,显著多于单用直径。作者认为扩张(45-54 mm)且延长(≥120 mm)的升主动脉是TAD高危亚群。
要点
- 升主动脉长度在对照组为92 mm,扩张组113 mm,动脉瘤组120 mm,夹层前组111 mm,TAD组118 mm。
- 升主动脉长度超过120 mm者在对照组占2%,扩张组31%,动脉瘤组50%,夹层前组24%,TAD组48%。
- 结合直径与长度的评分识别23.5%的夹层前患者,显著多于单用直径;31.4%的扩张主动脉存在延长。
核心结论
- 扩张(直径45-54 mm)且延长(≥120 mm)的升主动脉患者是TAD高危亚群。
研究设计与样本
- 采用曲线多平面重组分析CT血管造影,纳入256例健康、102例扩张、38例动脉瘤、17例夹层前及166例TAD主动脉。
- 扩张定义为升主动脉直径45-54 mm,动脉瘤定义为≥55 mm。
主要发现
- 升主动脉直径在对照组为35 mm,夹层前组43 mm,TAD组56 mm(均P < 0.001)。
- 升主动脉长度(主动脉瓣环至头臂干)在对照组为92 mm,扩张组113 mm,动脉瘤组120 mm,夹层前组111 mm,TAD组118 mm(均P < 0.001)。
- 升主动脉长度超过120 mm者在对照组占2%,扩张组31%,动脉瘤组50%,夹层前组24%,TAD组48%。
- 升主动脉直径与长度的相关性r = 0.752,两参数需分别评估。
- 结合直径与长度的评分识别23.5%的夹层前患者,显著多于单用直径;31.4%的扩张主动脉存在延长。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To study the lengths and diameters of aortic segments in healthy and diseased aortas and to assess the role of aortic elongation in Type A aortic dissection (TAD) prediction. METHODS: Ectasia and aneurysm were defined by ascending aorta diameters of 45-54 mm and ≥55 mm, respectively. Computed tomography angiography studies of 256 healthy, 102 ectasia, 38 aneurysm, 17 pre-TAD and 166 TAD aortas were analysed using curved multiplanar reformats. RESULTS: The study groups were structurally equal. The diameter of the ascending aorta was 35 mm in the control group and was larger (P < 0.001) in the pre-TAD (43 mm) and TAD (56 mm) groups. The length of the ascending aorta from the aortic annulus to the brachiocephalic trunk was 92 mm in the control group, 113 mm in the ectasia group, 120 mm in the aneurysm group and 111 mm and 118 mm in the pre-TAD and TAD groups (all P < 0.001 compared with the control group). An ascending aorta length of 120 mm was exceeded in 2% of the control group, 31% of the ectasia group, 50% of the aneurysm group, 24% of the pre-TAD group and 48% of the TAD group. The correlation between the diameter and the length of the ascending aorta was r = 0.752; therefore, both parameters must be examined separately. A score considering both parameters identified 23.5% of pre-TAD patients, significantly more than the diameter alone, and 31.4% of ectasia aortas were elongated. CONCLUSIONS: Patients with ectatic (45-54 mm diameter) and elongated (≥120 mm) ascending aortas represent a high-risk subpopulation for TAD.
引用
- Krüger T, Sandoval Boburg R, Lescan M, et al. Aortic elongation in aortic aneurysm and dissection: the Tübingen Aortic Pathoanatomy (TAIPAN) project. Eur J Cardiothorac Surg. 2018. PMID: 29373683. doi:10.1093/ejcts/ezx503