文献速递先天性心脏病外科瓣膜外科

法洛四联症矫正术中肺动脉瓣瓣环扩大联合瓣膜修复的长期结果

Long-term results of pulmonary valve annular enlargement with valve repair in tetralogy of Fallot.
PubMed 文献 · Eur J Cardiothorac Surg · 2018-01-01

本研究回顾了43例法洛四联症伴肺动脉狭窄患者接受肺动脉瓣瓣环扩大联合瓣膜修复的长期结果,术后平均随访131.9个月,再手术1例,末次超声平均肺动脉瓣反流分级1.59±0.60,平均压差22.7±9.9 mmHg;倾向性评分匹配显示该组中度及以上肺动脉瓣反流发生率低于单纯跨瓣环补片组(40% vs 68%,P=0.04)。

要点

  • 法洛四联症矫正术中肺动脉瓣瓣环扩大联合瓣膜修复无手术死亡。
  • 长期随访末次超声平均肺动脉瓣反流分级1.59±0.60,平均压差22.7±9.9 mmHg。
  • 倾向性评分匹配显示该组中度及以上肺动脉瓣反流发生率低于单纯跨瓣环补片组(40% vs 68%,P=0.04)。

核心结论

  • 肺动脉瓣瓣环扩大联合瓣膜修复的长期结果合理,与单纯跨瓣环补片扩大技术相比,长期显著肺动脉瓣反流发生率更低。

研究设计与样本

  • 回顾性分析2000年4月至2005年8月间43例(男性26例)法洛四联症伴肺动脉狭窄患者,接受肺动脉瓣瓣环扩大联合瓣膜修复,手术时中位年龄14个月,中位体重10.2 kg。

主要发现

  • 无手术死亡。
  • 出院时平均术后肺动脉瓣反流分级0.93±0.40(无或微量10例,轻度27例,轻至中度5例,中度1例),平均肺动脉瓣压差13.0±10.9 mmHg。
  • 平均随访131.9±42.9个月,随访期间因残余室间隔缺损再手术1例。
  • 末次随访超声平均肺动脉瓣反流分级1.59±0.60(轻度17例,轻至中度8例,中度14例,中至重度1例,重度3例),平均压差22.7±9.9 mmHg。
  • 倾向性评分匹配比较显示,肺动脉瓣修复组中度及以上肺动脉瓣反流发生率低于单纯跨瓣环补片组(40% vs 68%,P=0.04)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: We adopted an operative technique of pulmonary valve (PV) annular enlargement with valve repair in tetralogy of Fallot (TOF) correction to reduce postoperative pulmonary regurgitation (PR) 16 years ago. Here, we have evaluated the long-term results. METHODS: Between April 2000 and August 2005, 43 patients (26 men) with tetralogy of Fallot with pulmonary stenosis underwent PV annular enlargement with valve repair. The median age and body weight at the time of surgery were 14 months and 10.2 kg, respectively. RESULTS: There was no operative mortality. Mean postoperative PR grade at discharge was 0.93 ± 0.40 (none or trivial in 10 patients, mild in 27 patients, mild to moderate in 5 patients and moderate in 1 patient), and the mean postoperative pressure gradient across PV was 13.0 ± 10.9 mmHg. The mean follow-up duration was 131.9 ± 42.9 months. During follow-up, 1 reoperation was performed for residual ventricular septal defect. The mean PR grade at the last follow-up echocardiography was 1.59 ± 0.60 (mild in 17 patients, mild to moderate in 8 patients, moderate in 14 patients, moderate to severe in 1 patient and severe in 3 patients), and the mean pressure gradient was 22.7 ± 9.9 mmHg. We have compared the incidence of moderate or more PR with the incidence of patients who underwent simple transannular patch enlargement through propensity score matching. The PV repair group had a lower incidence of moderate or more PR compared with the simple transannular patch group (40% vs 68%, P = 0.04). CONCLUSIONS: PV annular enlargement with valve repair has reasonable long-term results and yields a lower long-term incidence of significant PR compared with the simple transannular patch enlargement technique.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Kim H, Sung SC, Choi KH, et al. Long-term results of pulmonary valve annular enlargement with valve repair in tetralogy of Fallot. Eur J Cardiothorac Surg. 2018. PMID: 29365090. doi:10.1093/ejcts/ezx497

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。