文献速递食管与纵隔外科

系列胸膜淀粉酶水平评估食管吻合口完整性

Evaluation of Esophageal Anastomotic Integrity With Serial Pleural Amylase Levels.
PubMed 文献 · Ann Thorac Surg · 2017-11-27

该研究回顾性分析了45例连续接受Ivor Lewis食管切除术患者的连续性胸膜淀粉酶(PAL)数据,以评估食管吻合口完整性。无漏患者PAL在术后第3天最高(中位数42 IU/L),清流质耐受后1天降至最低(中位数15 IU/L,p=0.04)。3例漏患者PAL峰值分别为227、630和超过4000 IU/L。作者认为系列PAL检测准确、安全且廉价,可能成为首选方法,但需前瞻性随机研究验证。

要点

  • 无漏患者PAL在术后第3天最高(中位数42 IU/L),清流质耐受后1天降至最低(中位数15 IU/L,p=0.04)。
  • 3例漏患者PAL峰值分别为227、630和超过4000 IU/L,其中1例漏前1天PAL仅55 IU/L。
  • 作者认为系列PAL检测准确、安全且廉价,可能成为食管切除术后检测吻合口漏的首选方法。

核心结论

  • 系列胸膜淀粉酶水平检测用于检测食管吻合口漏被证明是准确、安全且廉价的。
  • 取消钡餐和CT扫描评估吻合口完整性可能降低术后误吸风险及相关肺衰竭。
  • 系列PAL可能成为食管切除术后检测吻合口漏的首选方法,但需前瞻性随机研究验证。

研究设计与样本

  • 回顾性审查了18个月内连续45例接受Ivor Lewis食管切除术患者的前瞻性数据,用系列胸膜淀粉酶水平评估吻合口完整性。
  • 患者中男性40例(89%),中位年龄63岁(范围35至79岁)。
  • 食管切除术指征为癌症者38例(84%),其中27例(71%)接受新辅助放化疗。

主要发现

  • 前25例患者在中位术后第5天(范围5至10天)行钡餐检查,23例(93%)结果为阴性。
  • 无漏患者PAL在术后第3天最高(中位数42 IU/L;范围20至102 IU/L),清流质耐受后1天降至最低(中位数15 IU/L;范围8至34 IU/L),p=0.04。
  • 2例漏患者PAL峰值分别为227 IU/L和630 IU/L,均发生于术后第4天,即计划钡餐检查前1天。
  • 最后20例患者仅接受系列PAL检测,未计划行钡餐或CT扫描评估吻合口完整性;其中1例于术后第5天发生漏,前1天PAL为低值55 IU/L,随后升至超过4000 IU/L。
  • 3例漏中2例经食管支架置入和静脉抗生素治疗,另1例经静脉抗生素、禁食和仅观察后缓解;无漏患者需经胸食管修补或脓胸引流。

关键数值与推荐

  • 无漏患者PAL术后第3天中位数42 IU/L(范围20至102 IU/L),清流质耐受后1天中位数15 IU/L(范围8至34 IU/L),p=0.04。
  • 漏患者PAL峰值分别为227 IU/L和630 IU/L,另1例升至超过4000 IU/L。

临床怎么用

  • 作者认为系列PAL检测可能成为食管切除术后检测吻合口漏的首选方法。
  • 作者认为取消钡餐和CT扫描评估吻合口完整性可能降低误吸风险及相关肺衰竭。
  • 作者提出需前瞻性随机研究验证。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: An anastomotic leak is the most devastating and potentially fatal complication after esophagectomy. Current detection methods can be inaccurate and place patients at risk of other complications. Analysis of pleural fluid for amylase may be more accurate and place patients at less of a risk for evaluating the integrity of an esophageal anastomosis. METHODS: We retrospectively reviewed prospective data of 45 consecutive patients who underwent an Ivor Lewis esophagectomy over an 18-month period and evaluated their anastomotic integrity with serial pleural amylase levels (PAL). RESULTS: There were 40 men (89%), and median age was 63 years (range, 35 to 79). Indication for esophagectomy was cancer in 38 patients (84%); 27 (71%) underwent neoadjuvant chemoradiation. A barium swallow was performed in the first 25 patients at median postoperative day (POD) 5 (range, 5 to 10); the swallow was negative in 23 patients (93%). Serial PALs were obtained starting on POD 3 and stopped 1 day after toleration of clear liquids. The PALs in the no-leak patients were highest on POD 3 (median 42 IU/L; range, 20 to 102 IU/L) and decreased (median 15 IU/L; range, 8 to 34 IU/L) to the lowest levels 1 day after clear liquid toleration (p = 0.04). Two patients had a leak and had peak PALs of 227 IU/L and 630 IU/L, respectively; both leaks occurred on POD 4, 1 day before their scheduled swallow test. The last 20 patients underwent serial PALs only, without a planned swallow test or computed tomography scan for anastomotic integrity evaluation. One of these patients had a leak on POD 5 with a low PAL of 55 IU/L the day before the spike of more than 4,000 IU/L. Two of the leaks were treated with esophageal stent placement and intravenous antibiotics, and the remaining patient's leak resolved with intravenous antibiotics, no oral intake, and observation only. None of the leak patients required transthoracic esophageal repair or drainage of an empyema. There was 1 postoperative death (2%) secondary to aspiration pneumonia on POD 10; no leak was ever identified, and the patient had been eating for 3 days before death. Complications occurred in 15 patients (33%), most commonly respiratory; no respiratory issues occurred in PAL-only evaluated patients. No late anastomotic leaks occurred in any patient while in the hospital or after discharge. CONCLUSIONS: Serial PALs for the detection of esophageal anastomotic leaks proved to be accurate, safe, and inexpensive. Elimination of barium swallows and computed tomography scans for evaluation of anastomotic integrity may decrease aspiration risks as well as associated pulmonary failure during the postoperative period. Serial PALs may be the preferred method of detecting an anastomotic leak after esophagectomy. A prospective randomized study is warranted.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Miller DL, Helms GA, Mayfield WR, et al. Evaluation of Esophageal Anastomotic Integrity With Serial Pleural Amylase Levels. Ann Thorac Surg. 2017. PMID: 29191359. doi:10.1016/j.athoracsur.2017.07.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。