经鼻高流量氧疗改善非插管胸腔镜手术单肺通气期间的动脉氧合
该研究比较了30例非插管胸腔镜肺肿瘤手术患者使用经鼻湿化快速充气交换通气(THRIVE,流量20 l/min)与30例历史对照(氧气面罩,流量10 l/min)的氧合情况。结果显示THRIVE组术前及单肺通气期间动脉氧分压均显著高于面罩组,而动脉二氧化碳分压两组相当。结论认为THRIVE有效提高氧储备,使非插管胸腔镜手术更安全,但不促进二氧化碳排出。
要点
- THRIVE组术前动脉氧分压均值416.0 mmHg,显著高于面罩组的265.9 mmHg(P<0.01)。
- 单肺通气期间THRIVE组动脉氧分压均值207.0 mmHg,仍显著高于面罩组的127.8 mmHg(P=0.01)。
- 两组动脉二氧化碳分压在单肺通气前后相当,THRIVE未促进二氧化碳排出。
核心结论
- 结果表明THRIVE在单肺通气期间及麻醉后均有效增加氧储备。
- 若将流量可调的THRIVE纳入微创手术路径,非插管胸腔镜手术更安全,尽管未促进二氧化碳排出。
研究设计与样本
- 研究纳入2016年9月至2016年10月间30例因肺肿瘤行非插管胸腔镜手术并以THRIVE(流量20 l/min)维持通气的患者。
- 对照组为2015年9月至2016年7月间30例以氧气面罩(氧流量10 l/min)维持通气的历史对照患者,采用倾向性评分匹配算法进行比较。
主要发现
- 术前动脉氧分压THRIVE组均值416.0 mmHg vs 面罩组265.9 mmHg,THRIVE组显著更高(P<0.01)。
- 单肺通气期间动脉氧分压THRIVE组均值207.0 mmHg vs 面罩组127.8 mmHg,THRIVE组显著更高(P=0.01)。
- 动脉二氧化碳分压在单肺通气前后两组相当。
临床怎么用
- 原文结论指出,将流量可调的THRIVE纳入微创手术路径可使非插管胸腔镜手术更安全,尽管未促进二氧化碳排出。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Intraoperative hypoxaemia during one-lung ventilation (OLV) remains a major concern in thoracic surgery. Non-intubated video-assisted thoracic surgery (VATS) involves a greater risk of consequent emergent conversion to endotracheal intubation. Transnasal humidified rapid-insufflation ventilatory exchange (THRIVE) has recently been reported to be beneficial for higher oxygen reserves during difficult intubations and for enhancing postoperative recovery after thoracic surgery. However, the effects of THRIVE on oxygenation and carbon dioxide elimination before and during OLV in non-intubated VATS have not been investigated. METHODS: Between September 2016 and October 2016, 30 patients underwent non-intubated VATS for lung tumour and were maintained with THRIVE at a flow of 20 l/min. These patients were compared with a historical control group comprising 30 patients who were maintained with oxygen masks at an oxygen flow of 10 l/min using a propensity score matching algorithm between September 2015 and July 2016. RESULTS: The preoperative arterial oxygen tension was significantly higher in patients maintained with THRIVE than it was in patients maintained with oxygen masks (mean 416.0 vs 265.9 mmHg, P < 0.01). During OLV, arterial oxygen tension remained significantly higher in the THRIVE group than in the oxygen mask group (mean 207.0 vs 127.8 mmHg, P = 0.01). The arterial carbon dioxide tension was comparable before and during OLV. CONCLUSIONS: The results indicated that THRIVE effectively increases the oxygen reserve both during OLV and after anaesthesia. Furthermore, non-intubated VATS is safer if THRIVE with flow adjustment is incorporated into a minimally invasive surgical approach, although carbon dioxide elimination is not facilitated.
引用
- Wang ML, Hung MH, Chen JS, et al. Nasal high-flow oxygen therapy improves arterial oxygenation during one-lung ventilation in non-intubated thoracoscopic surgery. Eur J Cardiothorac Surg. 2018. PMID: 29253106. doi:10.1093/ejcts/ezx450
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。