文献速递肺外科

肺磨玻璃影肺癌局限切除术后前瞻性5年随访研究

A prospective 5-year follow-up study after limited resection for lung cancer with ground-glass opacity.
PubMed 文献 · Eur J Cardiothorac Surg · 2018-01-01

这项前瞻性多中心研究评估了符合特定标准的肺磨玻璃影(GGO)小腺癌行局限切除的有效性,共53例最终符合标准并接受楔形切除或肺段切除。术后60.0至126.3个月随访中无原发肺癌复发,5年疾病特异性生存率100%,总生存率98.1%,肺功能下降轻微,结论认为符合该研究标准的局限切除安全且肺功能保留良好。

要点

  • 符合GGO≥80%、肿瘤8-20mm等标准的肺腺癌行局限切除后5年无复发。
  • 5年疾病特异性生存率100%,总生存率98.1%。
  • 局限切除后肺功能下降轻微。

核心结论

  • 符合本研究标准的GGO小肺癌行局限切除安全且无复发,术后肺功能保留良好。

研究设计与样本

  • 前瞻性多中心研究,2006年11月至2012年4月从13家机构入组73例,最终53例符合标准。
  • 入选标准为年龄25-80岁、未接受过治疗、肿瘤最大径8-20mm、GGO比例≥80%、临床T1N0M0、18F-氟脱氧葡萄糖摄取低于纵隔、可行亚肺叶切除、能耐受肺叶切除且术中病理诊断为细支气管肺泡癌。
  • 优先楔形切除,允许肺段切除;分析疾病特异性生存率和总生存率。

主要发现

  • 最终符合标准的53例中,39例行楔形切除、14例行肺段切除;平均肿瘤大小14.0mm,平均GGO比例95.9%。
  • 截至2017年5月1日,术后60.0-126.3个月随访中无原发肺癌复发,2例死于其他疾病。
  • 5年疾病特异性生存率100%,总生存率98.1%。
  • 局限切除后肺功能下降轻微。

临床怎么用

  • 作者认为,符合本研究标准的GGO小肺癌行局限切除结局令人满意。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The incidence of small-sized pulmonary adenocarcinomas with ground-glass opacity (GGO) has recently increased, with excellent postoperative prognosis. The limited resection of such cancers has been deemed to be acceptable based on retrospective studies. We conducted a prospective multi-institutional study evaluating the validity of limited resection for small-sized pulmonary adenocarcinoma with GGO. METHODS: The inclusion criteria were 25-80 years of age, no prior treatment, a maximum tumour diameter of 8-20 mm, a GGO ratio of ≥ 80%, clinical T1N0M0, lower 18F-fluorodeoxyglucose accumulation than the mediastinum, resectable by sublobar resection, pulmonary lobectomy tolerable and an intraoperative pathological diagnosis of bronchiloalveolar carcinoma. Wedge resection was preferred, but segmentectomy was permitted. Disease-specific survival and overall survival were analysed. RESULTS: From November 2006 to April 2012, 73 patients were enrolled from 13 institutions. One patient was ineligible, and the remaining 72 patients were preregistered. The tumours of 3 and 14 patients were intraoperatively diagnosed as benign lesions and adenocarcinomas with mixed subtype, respectively. Intraoperative cytological/histological examination of surgical margin was not performed in 2 patients, and the remaining 53 patients were ultimately eligible for this study. The mean tumour size was 14.0 mm and the mean GGO ratio was 95.9%. Thirty-nine and 14 patients underwent wedge resection and segmentectomy, respectively. Although all tumours were intraoperatively diagnosed as bronchioloalveolar carcinomas, 6 were ultimately diagnosed as adenocarcinoma with a mixed subtype. No completion lobectomy was performed. As of 1 May 2017, no recurrence of the original lung cancer was observed during 60.0-126.3 months after surgery. Two patients died from other diseases. The 5-year disease-specific and overall survival rates were 100% and 98.1%, respectively. The reduction in the pulmonary function after limited resection was minimal. CONCLUSIONS: With these criteria, limited resection was performed safely without any recurrence, and the postoperative pulmonary function was well preserved. The outcomes of limited resection for small-sized lung cancer with GGOs that met the criteria of this study were satisfactory.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Sagawa M, Oizumi H, Suzuki H, et al. A prospective 5-year follow-up study after limited resection for lung cancer with ground-glass opacity. Eur J Cardiothorac Surg. 2018. PMID: 29236995. doi:10.1093/ejcts/ezx418

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。