Norwood手术中左肺动脉补片扩大可改善肺灌注
本研究对51例左心发育不良综合征(HLHS)患者行心血管磁共振成像评估左肺动脉(LPA)解剖与肺灌注,其中20例在改良Norwood手术中扩大LPA(N组),31例在hemi-Fontan手术中扩大(HF组)。结果显示N组LPA横截面积和区域肺灌注均显著优于HF组,且总体手术时间更短。
要点
- N组LPA横截面积中位数显著高于HF组(49.5 vs 27.9 mm2/m2,p<0.0001)。
- N组左侧肺灌注信号上升斜率显著改善(0.67 vs 0.40 s-1,p=0.002),右侧亦显著改善(0.84 vs 0.52 s-1,p=0.01)。
- N组hemi-Fontan旁路及手术总时间均显著更短(均p<0.001)。
核心结论
- 改良Norwood手术中行LPA补片扩大的HLHS患者,其LPA横截面积显著更高、肺灌注改善且总体手术时间更短,这一有前景的技术可能长期改善Fontan循环血流动力学。
研究设计与样本
- 连续51例HLHS患者接受心血管磁共振成像研究,评估LPA解剖与肺灌注;20例在改良Norwood手术中扩大LPA(N组),31例在hemi-Fontan手术中扩大(HF组)。
主要发现
- N组LPA横截面积中位数显著高于HF组(49.5 vs 27.9 mm2/m2,p<0.0001)。
- N组左侧肺灌注信号上升斜率显著高于HF组(0.67 s-1 vs 0.40 s-1,p=0.002)。
- N组右侧肺灌注信号上升斜率显著高于HF组(0.84 s-1 vs 0.52 s-1,p=0.01)。
- N组hemi-Fontan旁路及手术总时间均显著短于HF组(均p<0.001)。
临床怎么用
- 本研究中心将LPA补片扩大作为hemi-Fontan手术的常规组成部分,但在改良Norwood手术中扩大LPA可能具有手术优势。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Optimal pulmonary perfusion is crucial for a well-functioning Fontan circulation in patients with hypoplastic left heart syndrome (HLHS). To obtain an adequate size of the left pulmonary artery (LPA), patch enlargement is a routine part of the hemi-Fontan procedure in our center. However, LPA patch enlargement at the time of the modified Norwood procedure may have surgical advantages. Therefore, the aim of this study was to evaluate whether anatomic and functional effects of the new approach are superior. METHODS: A total of 51 consecutive HLHS patients underwent a cardiovascular magnetic resonance imaging study including assessment of LPA anatomy and lung perfusion. The LPA of 20 patients was enlarged during the modified Norwood procedure (group N) and of 31 patients during the hemi-Fontan procedure (group HF). RESULTS: The median indexed cross-sectional area of the LPA in group N was significantly higher than in group HF (49.5 versus 27.9 mm2/m2, p < 0.0001). The regional pulmonary perfusion as measured by first-pass, contrast-enhanced signal intensity upslope was significantly improved in group N (left side 0.67 s-1 versus 0.40 s-1, p = 0.002; right side 0.84 s-1 versus 0.52 s-1, p = 0.01). The total hemi-Fontan bypass and procedure times were significantly shorter in group N (both p < 0.001). CONCLUSIONS: These first magnetic resonance imaging data show that HLHS patients after LPA patch enlargement during the modified Norwood procedure have significantly higher LPA cross-sectional areas and show improved lung perfusion and shorter overall procedure time as compared with LPA patching during second stage (hemi-Fontan). Therefore, this promising surgical technique may improve blood flow dynamics of the Fontan circulation in the long run.
引用
- Salehi Ravesh M, Scheewe J, Attmann T, et al. Improved Lung Perfusion After Left Pulmonary Artery Patch Enlargement During the Norwood Operation. Ann Thorac Surg. 2017. PMID: 29288017. doi:10.1016/j.athoracsur.2017.11.057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。