文献速递瓣膜外科

瓣叶折叠夹可作为二尖瓣折叠成形术的有效手术模板

A leaflet plication clip is an effective surgical template for mitral valve foldoplasty.
PubMed 文献 · Eur J Cardiothorac Surg · 2018-01-01

研究在体内外猪心后叶完全脱垂模型中,用瓣叶折叠夹引导缝线折叠成形术。离体测试显示缝线后瓣叶宽度与单独使用夹子相当,均显著小于连枷宽度。体内7只猪修复后对合高度恢复,二尖瓣反流由中重度降至轻度或以下,后3只加用De-Vega瓣环成形术后残余漏消失。

要点

  • 折叠夹可辅助确定折叠成形术的正确位置、宽度、高度和方向。
  • 体内修复后二尖瓣反流由中重度降至轻度或以下。
  • 后3只动物加用De-Vega瓣环成形术后残余漏降至微量或无。

核心结论

  • 应用可调节瓣叶折叠夹有助于准确确定折叠成形术的正确位置、宽度、高度和方向。
  • 任何必要的夹子重新定位均在放置缝线之前完成,避免重新缝合。
  • 该方法可能有助于提高折叠成形修复的简便性和可重复性。

研究设计与样本

  • 在体内和离体猪心中,通过切断支撑中间扇贝的腱索建立二尖瓣后叶完全脱垂模型。
  • 离体测试中,应用折叠夹进行瓣叶折叠成形,随后以夹子为模板放置缝线并移除夹子。
  • 体内修复与评估在7只猪中进行,于心肺转流后恢复1小时和6小时评估正常生理负荷下的修复效果。

主要发现

  • 离体测试中,缝线放置后瓣叶宽度与单独使用夹子相当(7.0 ± 1.4 vs 9.0 ± 1.6),两者均显著小于连枷宽度15.7 ± 2.5 mm。
  • 体内修复后平均对合高度在恢复后1小时和6小时分别为4.7 ± 1.4 mm和4.2 ± 1.3 mm,基线高度为5.5 ± 0.9 mm。
  • 二尖瓣反流由中重度降至轻度或以下。
  • 最后3只动物加用De-Vega瓣环成形术后,残余漏降至微量或无。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: During mitral valve repair using the foldoplasty technique, correct judgement of the necessary dimensions and orientation of the leaflet fold is a critical but challenging step that can affect the chances of successful repair. In this study, we investigated whether a leaflet plication clip can be used to guide suture foldoplasty for posterior leaflet prolapse of the mitral valve. METHODS: Complete posterior leaflet prolapse was created in both in vivo and ex vivo pig hearts by severing the chordae supporting the middle scallop. A plication clip was applied to perform leaflet foldoplasty. Sutures were then placed using the clip as a template and the clip was removed. Leaflet width after flail creation, clip application and suture placement was determined in an ex vivo test. In vivo repair and evaluation was then performed in 7 pigs to determine the repair efficacy under normal physiological loading, at 1 and 6 h after recovery from cardiopulmonary bypass. RESULTS: Leaflet width after suture placement was comparable to the clip alone (7.0 ± 1.4 vs 9.0 ± 1.6) and both were significantly less than the flail width 15.7± 2.5 mm. In vivo, average coaptation height following repair was restored to 4.7 ± 1.4 mm and 4.2 ± 1.3 mm at 1 and 6 h, respectively, after recovery compared with the baseline height of 5.5 ± 0.9 mm. Mitral regurgitation was reduced from moderate-severe to mild or less, and addition of a De-Vega annuloplasty in the last 3 animals abolished residual leaks to trivial or none. CONCLUSIONS: Application of the adjustable leaflet plication clip facilitated accurate determination of the correct position, width, height and orientation of the foldoplasty. Any necessary clip repositioning was made prior to the placement of sutures avoiding the need to redo the sutures. This approach could potentially help improve the ease and reproducibility of the foldoplasty repair.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Wamala I, Saeed M, Ghelani SJ, et al. A leaflet plication clip is an effective surgical template for mitral valve foldoplasty. Eur J Cardiothorac Surg. 2018. PMID: 29220425. doi:10.1093/ejcts/ezx423