文献速递主动脉外科瓣膜外科

正常三叶主动脉瓣游离缘长度与对合面积的解剖学研究

Free margin length and coaptation surface area in normal tricuspid aortic valve: an anatomical study.
PubMed 文献 · Eur J Cardiothorac Surg · 2018-01-01

该解剖学研究分析了25例主动脉根部同种移植物的正常三叶主动脉瓣,测量游离缘长度(FML)和对合面积及其与瓣膜和根部尺寸的关系。结果显示平均FML为34.3 ± 3.1 mm,三个瓣叶间相似,FML与所有其他瓣膜和根部测量值相关;平均每瓣叶对合面积为122 ± 21 mm2,占瓣叶面积的41%。作者认为这些测量值将有助于进一步开发基于术中FML测量进行游离缘缩短的客观方法。

要点

  • 正常三叶主动脉瓣平均FML为34.3 ± 3.1 mm,三个瓣叶间相似。
  • FML与几何高度的比值为1.81,游离缘长度/窦管交界为1.29。
  • 平均每瓣叶对合面积为122 ± 21 mm2,占瓣叶面积的41%。

核心结论

  • 描述了三叶主动脉瓣FML和对合面积的正常尺寸,这些测量值将有助于进一步开发基于术中FML测量进行游离缘缩短的客观方法,以治疗瓣叶脱垂和保瓣手术后的低对合。

研究设计与样本

  • 解剖学研究,分析25例主动脉根部同种移植物,从新鲜标本获取8项瓣膜和根部测量值,包括在适当张力下测量游离缘长度,随后在压力下以舒张位福尔马林固定以测量对合面积。

主要发现

  • 平均FML为34.3 ± 3.1 mm,三个瓣叶间相似,且与所有其他瓣膜和根部测量值相关。
  • FML与几何高度的比值为1.81,游离缘长度/窦管交界为1.29。
  • 平均每瓣叶对合面积为122 ± 21 mm2,相当于瓣叶面积的41%。
  • 中央对合长度为3.3 ± 0.8 mm,侧方对合长度为5.9 ± 0.6 mm。
  • 每个标本的总对合面积为184 ± 32 mm2。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Aortic cusp free margins are a central target in most aortic valve repair operations to optimize valve coaptation. The objective of this anatomical study was to analyse the normal dimensions of free margin length (FML) and coaptation surface and to analyse their relationship with other valve and root dimensions in normal tricuspid aortic valves. METHODS: We analysed 25 aortic root homografts. Eight valve and root measurements were obtained from fresh specimens including the length of the free margin while applying appropriate tension on the structures. The valves were then fixed with formalin in the diastolic position under pressure to allow measurement of the coaptation surface. In addition to normal values, we analysed the correlations and ratios between the different measures. RESULTS: The mean FML was 34.3 ± 3.1 mm. The FML was similar between the 3 cusps and correlated with all other valve and root measures. The ratio of the FML to the geometric height was 1.81, and the free edge length/sinotubular junction was 1.29. The mean coaptation surface was 122 ± 21 mm2 per cusp and corresponded to 41% of the cusp surface. The central coaptation length was 3.3 ± 0.8 mm, and the lateral coaptation length was 5.9 ± 0.6 mm. The total coaptation surface per specimen was 184 ± 32 mm2. CONCLUSIONS: We described the normal dimensions of the FML and coaptation surface in the tricuspid aortic valve. These measurements will serve in the further development of an objective method of free margin shortening based on intraoperative measurements of the FML to treat cusp prolapse and low coaptation after valve-sparing surgery.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. De Kerchove L, Momeni M, Aphram G, et al. Free margin length and coaptation surface area in normal tricuspid aortic valve: an anatomical study. Eur J Cardiothorac Surg. 2018. PMID: 29253123. doi:10.1093/ejcts/ezx456