心脏瓣膜手术冠状动脉筛查比较效果:计算机断层扫描与常规冠状动脉造影
该研究纳入2001至2015年间3150例择期瓣膜手术患者,其中1402例行冠状动脉计算机断层扫描血管成像(CCTA),1748例行常规冠状动脉造影(CAG)筛查冠心病。结果显示CT组显著冠心病检出率(4.9% vs 9.7%,P<.001)和接受冠状动脉旁路移植术比例(2.9% vs 4.3%,P=.041)均低于CAG组,低心输出量综合征发生率高于CAG组(2.3% vs 1.0%,P=.008),30天死亡率两组相似(2.1% vs 1.7%,P=.463)。
要点
- CT组显著冠心病检出率4.9%,低于CAG组9.7%(P<.001)。
- CT组接受冠状动脉旁路移植术比例2.9%,低于CAG组4.3%(P=.041)。
- CT组低心输出量综合征发生率2.3%,高于CAG组1.0%(P=.008)。
核心结论
- 在择期心脏瓣膜手术患者中,CCTA对显著冠心病的检出和冠状动脉旁路移植术候选者的识别劣于常规CAG。
研究设计与样本
- 研究纳入2001年至2015年间3150例年龄>40岁或具有冠状动脉危险因素的连续择期瓣膜手术患者,其中1402例行CCTA(CT组),1748例行常规CAG(CAG组)进行冠心病筛查。
主要发现
- 30天死亡率两组相似:CT组2.1% vs CAG组1.7%(P=.463)。
- 低心输出量综合征发生率CT组2.3% vs CAG组1.0%(P=.008),CT组更高。
- 显著冠心病(狭窄≥50%)检出率CT组4.9% vs CAG组9.7%(P<.001),CT组更低。
- 接受冠状动脉旁路移植术比例CT组2.9% vs CAG组4.3%(P=.041),CT组更低。
- 倾向性评分匹配(563对)后,CT组较CAG组冠心病检出率更低(OR 0.56;95%CI 0.36-0.85),冠状动脉旁路移植术率更低(OR 0.47;95%CI 0.26-0.81),早期死亡风险相似(OR 1.51;95%CI 0.54-4.52),低心输出量综合征风险更高(OR 3.30;95%CI 1.16-11.78)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although conventional coronary angiography (CAG) is considered the gold standard for coronary artery disease (CAD) screening in the setting of heart valve surgery, coronary artery computed tomography angiography (CCTA) has emerged as an alternative modality. This study was conducted to evaluate the clinical outcomes of CCTA compared with conventional CAG for CAD screening in patients undergoing heart valve surgery. METHODS: A total of 3150 consecutive patients aged >40 years or with coronary risk factors undergoing elective valve operations between 2001 and 2015 were evaluated. Of these, 1402 patients underwent CCTA (CT group) and 1748 patients underwent conventional CAG (CAG group) for CAD screening. RESULTS: The 30-day mortality rates were similar in the 2 groups (2.1% in the CT group vs 1.7% in the CAG group; P = .463); however, the incidence of low cardiac output syndrome was higher in the CT group (2.3% vs 1.0%; P = .008). The final rate of detection of significant CAD (≥50% stenosis) (4.9% vs 9.7%; P < .001) and proportion of receiving coronary bypass grafting (CABG) (2.9% vs 4.3%; P = .041) were lower in the CT group. After adjustment by propensity score matching (563 pairs), the main findings of our crude analyses did not change, with lower rates of CAD detection (odds ratio [OR], 0.56; 95% confidence interval [CI], 0.36-0.85) and CABG (OR, 0.47; 95% CI, 0.26-0.81), a similar risk of early mortality (OR, 1.51; 95% CI, 0.54-4.52), but a higher risk of low cardiac output syndrome (OR, 3.30; 95% CI, 1.16-11.78) in the CT group compared with the CAG group. CONCLUSIONS: The detection of significant CAD and identification of candidates for CABG were inferior with CCTA compared with conventional CAG in patients scheduled for elective heart valve operations.
引用
- Lee W, Kim JB, Yang DH, et al. Comparative effectiveness of coronary screening in heart valve surgery: Computed tomography versus conventional coronary angiography. J Thorac Cardiovasc Surg. 2017. PMID: 29246551. doi:10.1016/j.jtcvs.2017.10.128
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。