超声能量在VATS肺叶切除术中封闭肺动脉分支安全性的1期试验
该1期试验前瞻性纳入计划行VATS肺叶切除术的患者,评估超声能量血管封闭装置封闭直径≤7 mm肺动脉分支的安全性。
要点
- 超声能量装置可安全封闭VATS肺叶切除术中直径≤7 mm的肺动脉分支。
- 无术中或术后出血与超声PA分支封闭相关,无术后死亡。
核心结论
- 在VATS肺叶切除术中,使用超声能量血管封闭装置封闭直径≤7 mm的肺动脉分支可安全实现。
- 在广泛临床应用前,仍需大规模、前瞻性、多中心研究进一步验证。
研究设计与样本
- 1期试验,前瞻性纳入计划行VATS肺叶切除术的患者,目标样本量20例。
- 直径≤7 mm的PA分支使用超声能量血管封闭装置封闭并切断,其余肺叶切除术按标准方式进行。
- 前瞻性记录术中、住院期间及术后30天出血情况。
主要发现
- 使用该装置封闭的血管平均直径为4 mm。
- 2例中转开胸(1例分离时PA损伤,1例PA肿瘤侵犯)。
- 无术中或术后出血与超声PA分支封闭相关,无术后死亡。
关键数值与推荐
- 目标样本量20例患者。
- PA分支直径≤7 mm为使用超声能量血管封闭装置的条件。
- 使用该装置封闭的血管平均直径为4 mm。
临床怎么用
- 在VATS肺叶切除术中,对直径≤7 mm的肺动脉分支可考虑使用超声能量血管封闭装置进行封闭。
- 需注意术前或术中评估PA分支直径,直径超过7 mm者不适用该装置。
- 应用前应知晓仍需大规模多中心研究验证,当前证据来自小样本1期试验。
局限性
- 单中心、非多中心研究,广泛临床适用性有限。
- 需大规模、前瞻性、多中心研究进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Energy-sealing devices may be useful to divide small pulmonary arteries (PAs) during video-assisted thoracoscopic surgery (VATS) lobectomy. We evaluated the safety of PA branch sealing with an ultrasonic energy vessel-sealing device during VATS lobectomy. METHODS: The study consisted of a phase 1 trial. Patients planned to undergo VATS lobectomy were prospectively enrolled. Target sample size was 20 patients. Branches of 7 mm or less were sealed and cut with an ultrasonic energy vessel-sealing device. The remainder of the lobectomy was performed in a standard fashion. Intraoperative, in-hospital, and 30-day postoperative bleeding were prospectively recorded. RESULTS: Thirty-three patients were prospectively enrolled. Thirteen patients were not amenable to PA sealing with the vessel-sealing device because all PA branch diameters exceeded 7 mm (n = 10), conversion to thoracotomy (n = 2), and lobectomy not performed (n = 1). A minimum of one PA branch was sealed with the device in 20 patients. Fifty-eight PA branches were divided in 20 patients: 31 with ultrasonic device, 24 with endostaplers, 2 with clips, and 1 with sutures. The mean vessel diameter sealed with the device was 4 mm. Two patients were converted to thoracotomy (1 with PA injury during dissection, 1 with PA tumor invasion). No intraoperative or postoperative bleeding was related to ultrasonic PA branch sealing. No postoperative deaths occurred. CONCLUSIONS: PA branch sealing for vessels 7 mm or less was safely achieved using an ultrasonic energy vessel-sealing device in VATS lobectomy. Large-scale, prospective, multi-institutional studies are necessary before widespread clinical application of energy for PA branch sealing in VATS lobectomy.
引用
- Goudie E, Oliveira RL, Thiffault V, et al. Phase 1 Trial Evaluating Safety of Pulmonary Artery Sealing With Ultrasonic Energy in VATS Lobectomy. Ann Thorac Surg. 2017. PMID: 29157742. doi:10.1016/j.athoracsur.2017.08.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。