文献速递主动脉外科

B型主动脉夹层TEVAR术后远端再破口新分支技术封闭

Distal re-entry closure with neobranching technique after thoracic endovascular aortic repair of Type B aortic dissection.
PubMed 文献 · Eur J Cardiothorac Surg · 2018-01-01

本文报告一例67岁男性B型主动脉夹层患者,在发病7周后因真腔严重受压和内脏灌注不良行胸主动脉腔内修复术(TEVAR)。术中造影显示近端破口已封闭,但经远端再破口的逆行血流导致假腔血流增加。采用新分支技术,经远端再破口从主动脉真腔向内脏动脉置入覆膜支架,完成再破口封闭。

要点

  • TEVAR术后逆行假腔血流可影响主动脉重塑并阻碍假腔减压。
  • 新分支技术可经远端再破口从真腔向内脏动脉置入覆膜支架。
  • 该技术可用于TEVAR术后因再破口逆行血流需额外干预的病例。

核心结论

  • 对于B型主动脉夹层TEVAR术后因远端再破口逆行血流导致假腔血流增加的患者,可采用新分支技术经再破口置入覆膜支架封闭破口。

研究设计与样本

  • 个案报告:一名67岁男性B型主动脉夹层患者,发病7周后因真腔严重受压和内脏灌注不良行TEVAR。

主要发现

  • 术中造影显示近端破口已封闭,但经远端再破口的逆行血流导致假腔血流增加。
  • 额外采用新分支技术,经远端再破口从主动脉真腔向内脏动脉置入覆膜支架,完成再破口封闭。

临床怎么用

  • TEVAR术后应关注远端再破口导致的逆行假腔血流,必要时可采用新分支技术经再破口置入覆膜支架进行封闭。

局限性

  • 本文为个案报告,技术安全性和有效性需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Retrograde false-lumen flow after thoracic endovascular aortic repair of Type B aortic dissection occurs occasionally and may have a negative impact on aortic remodelling and even prevent the decompression of the false lumen. A 67-year-old man with a Type B aortic dissection underwent thoracic endovascular aortic repair for severe compression of the true lumen and visceral malperfusion 7 weeks after the onset. Intraoperative angiography revealed proximal entry tear closure, but the false-lumen flow increased because of retrograde flow through the re-entry tear. Additional intervention including re-entry tear closure was performed with a neobranching technique with covered stent placement in the visceral artery from the aortic true lumen through the distal re-entry tear. We report a case of Type B aortic dissection and discuss the surgical techniques used.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Yamamoto M, Fukutomi T, Noguchi T, et al. Distal re-entry closure with neobranching technique after thoracic endovascular aortic repair of Type B aortic dissection. Eur J Cardiothorac Surg. 2018. PMID: 29136130. doi:10.1093/ejcts/ezx384

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。