胸主动脉腔内修复远端锚定区支架释放不准确的发病率、原因与后果
本研究回顾195例非夹层胸主动脉病变TEVAR患者,其中59例远端锚定区不足40mm。按支架距目标血管≤5mm或>5mm分为准确释放组(10例)和不准确释放组(49例)。不准确释放组原发性Ib型内漏发生率显著高于准确释放组(33% vs 0%,P=0.049)。
要点
- 远端锚定区不足40mm时,现有释放机制下准确释放常具挑战性。
- 不准确释放与更高的原发性Ib型内漏发生率相关(33% vs 0%,P=0.049)。
- 支架楔形贴壁在两组间无显著差异(30% vs 39%,P=0.73)。
核心结论
- 使用现有释放机制在远端锚定区准确植入支架常具挑战性。
- 不准确释放与更高的原发性Ib型内漏发生率相关。
研究设计与样本
- 其中59例远端锚定区短于40mm,中位年龄73岁(Q1 68;Q3 77),女性20例。
- 按支架距目标血管≤5mm或>5mm分为准确释放组(n=10)和不准确释放组(n=49)。
- 中位随访23个月(5;48)。
主要发现
- 总体支架距目标血管距离为10.0mm(6.5mm;16.0mm)。
- 3例需在远端锚定区植入第二枚支架,另3例目标血管被意外覆盖。
- 准确释放组原发性Ib型内漏发生率为0%,不准确释放组为33%(P=0.049)。
- 准确释放组3例(30%)和不准确释放组19例(39%)存在明显支架楔形贴壁(P=0.73)。
- 两组远端锚定区解剖无差异。
临床怎么用
- TEVAR术中应关注远端锚定区释放精度,不准确释放增加Ib型内漏风险。
- 对远端锚定区不足40mm的患者,需警惕现有释放机制下不准确释放的可能性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The aim of this study was to investigate the accuracy of stent graft deployment in the distal landing zone (LZ) during thoracic endovascular aortic repair (TEVAR). Currently, TEVAR focuses on accurate stent graft deployment in the proximal LZ. Data on landing in the distal LZ are lacking. METHODS: Of 195 TEVAR patients (2005-16) with a non-dissected aortic pathology, 59 [median age 73 years (first quartile 68; third quartile 77), 20 women] patients had a distal LZ shorter than 40 mm. In all, the aim was to deploy the stent graft just above the target vessel (coeliac trunk, mesenteric superior or renal artery). Patients were divided into the accurate landing (n = 10) and inaccurate landing (IAL, n = 49) groups according to the distance to the target vessel ≤ 5 mm or > 5 mm after TEVAR, target vessel coverage and the need for a second stent graft in the distal LZ. We assessed the distal LZ, stent graft distance to the target vessel, apposition, migration and endoleak Ib on computed tomography. Median follow-up period was 23 months (5; 48). RESULTS: Distal LZ anatomy did not differ between groups. Overall stent graft distance to the target vessel was 10.0 mm (6.5 mm; 16.0 mm). Three patients required a second stent graft in the distal LZ, and in 3 others, the target vessel was accidentally covered. In patients of the accurate landing group primary endoleak Ib occurred less frequently than those in the IAL group (0% vs 33%; P = 0.049). Three (30%) accurate landing and 19 (39%) IAL patients (P = 0.73) presented with substantial stent graft wedge apposition. CONCLUSIONS: Accurate stent graft implantation in the distal LZ with the currently available deployment mechanism is often challenging. An inaccurate landing is associated with a higher incidence of endoleak Ib.
引用
- Berezowski M, Morlock J, Beyersdorf F, et al. Inaccurate aortic stent graft deployment in the distal landing zone: incidence, reasons and consequences. Eur J Cardiothorac Surg. 2018. PMID: 29136140. doi:10.1093/ejcts/ezx379
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。