文献速递瓣膜外科主动脉外科

二叶式主动脉瓣置换时是否应同期修复扩张的升主动脉?

Should the dilated ascending aorta be repaired at the time of bicuspid aortic valve replacement?
PubMed 文献 · Eur J Cardiothorac Surg · 2018-01-01

本研究比较了1301例二叶式主动脉瓣合并扩张主动脉的成人患者,分别接受单纯主动脉瓣置换(AVR-only)与AVR联合主动脉修复(AVR-AR)的死亡和再手术结局。随访1年内再手术率1.8%、死亡率5.4%,未观察到主动脉夹层,两组间再手术或死亡结局无显著差异。年龄、主动脉尺寸或其组合均未显示AVR-AR优于AVR,结果不支持现行指南推荐的45 mm主动脉切除阈值。

要点

  • AVR-only与AVR-AR在二叶式主动脉瓣合并扩张主动脉患者中死亡和再手术结局无显著差异。
  • 1年内再手术率1.8%、死亡率5.4%,随访期间未发生主动脉夹层。
  • 结果不支持现行指南推荐的45 mm主动脉切除阈值。

核心结论

  • AVR-only与AVR-AR手术在广泛年龄和主动脉尺寸范围内均具有低并发症和死亡率,结果不支持现行指南推荐的45 mm主动脉切除阈值。

研究设计与样本

  • 采用Cox比例风险模型和患者匹配,比较1301例二叶式主动脉瓣合并扩张主动脉成人接受AVR-only与AVR-AR的死亡和再手术结局。

主要发现

  • 两组患者特征、主动脉瓣功能和主动脉尺寸存在临床重要差异。
  • 1年内再手术率和死亡率分别为1.8%和5.4%,随访期间未观察到主动脉夹层。
  • AVR-only与AVR-AR组间再手术或死亡结局无显著差异。
  • 年龄、主动脉尺寸或其组合与AVR-AR相比AVR的结局优劣无关。

关键数值与推荐

  • 1年内再手术率1.8%,死亡率5.4%。
  • 随访期间主动脉夹层发生率为0。
  • 现行指南推荐AVR时主动脉切除阈值为45 mm,但本研究结果不支持该阈值。

临床怎么用

  • 在二叶式主动脉瓣合并扩张主动脉患者中,AVR-only和AVR-AR均可考虑,需结合个体情况决策。
  • 不应仅依据45 mm阈值常规决定同期主动脉切除。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Bicuspid aortic valve (BAV) is the most common congenital valvular abnormality and frequently presents with accelerated calcific aortic valve disease, requiring aortic valve replacement (AVR) and thoracic aortic aneurysm and dissection. Supporting evidence for Association Guidelines of aortic dimensions for aortic resection is sparse. We sought to determine whether concurrent repair of dilated or aneurysmal aortic disease during AVR in patients with BAV substantially improves morbidity and mortality outcomes. METHODS: Mortality and reoperation outcomes of 1301 adults with BAV and dilated aorta undergoing AVR-only surgery were compared to patients undergoing AVR with aortic resection (AVR-AR) using Cox proportional hazards modelling and patient matching. RESULTS: Clinically important differences in patient characteristics, aortic valve function and aortic dimensions were identified between cohorts. Event rates were low, with rates of reoperation and death within 1 year of only 1.8% and 5.4%, respectively, and no aortic dissection observed during follow-up. There were no significant differences in reoperation or mortality outcomes between the AVR-only and AVR-AR cohorts. Age, aortic dimension or a combination thereof was not associated with better or worse outcomes after each AVR-AR compared with AVR. CONCLUSIONS: We conclude AVR-only and AVR-AR surgery have low morbidity and mortality and have utility over a wide range of age and aortic sizes. Our results do not provide support for the 45-mm aortic dimension recommended in the current guidelines for aortic resection while performing AVR or any other specific dimension.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Kaneko T, Shekar P, Ivkovic V, et al. Should the dilated ascending aorta be repaired at the time of bicuspid aortic valve replacement? Eur J Cardiothorac Surg. 2018. PMID: 29149323. doi:10.1093/ejcts/ezx387

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。