膨体聚四氟乙烯带瓣管道植入的中期结局
本研究分析自行设计的膨体聚四氟乙烯(ePTFE)带瓣管道用于右心室流出道重建的中期效果。2012年起共植入26例,中位年龄9.8岁,平均随访2.6年,无住院死亡和管道再手术,仅1例因远端吻合口狭窄再干预,92%患者肺动脉瓣反流轻度或以下。结论认为其中期表现优于其他肺动脉瓣替代方案的历史数据。
要点
- ePTFE带瓣管道用于右心室流出道重建,中期无管道相关再手术。
- 92%患者肺动脉瓣反流为轻度或以下,仅1例因吻合口狭窄再干预。
- 平均随访2.6年,右室-肺动脉平均峰值压差22.4±15.1 mmHg。
核心结论
- 与其它肺动脉瓣替代方案的历史数据相比,ePTFE带瓣管道中期表现更优,再干预或显著瓣膜功能障碍更少。
研究设计与样本
- 单中心回顾性分析,2012年起连续纳入26例接受ePTFE带瓣管道植入的患者,中位年龄9.8岁(范围1.0至15.9岁)。
- 前3例使用二瓣叶管道,后23例使用三瓣叶管道;管道由商用ePTFE管(16 mm 1例,20 mm 7例,24 mm 18例)和0.1 mm厚ePTFE膜瓣叶制作。
主要发现
- 无术后住院死亡。
- 平均随访2.6年(范围4个月至4.7年),无ePTFE管道再手术。
- 1例因远端吻合口狭窄再干预。
- 24例(92%)肺动脉瓣反流为轻度或以下。
- 最近随访时右心室与肺动脉间平均峰值瞬时压差为22.4 ± 15.1 mm Hg。
临床怎么用
- 对于需肺动脉瓣替代的青少年和年轻成人,ePTFE带瓣管道可作为可选方案之一,中期再干预率低。
- 术后需超声心动图评估瓣膜功能,关注吻合口狭窄和肺动脉瓣反流。
局限性
- 样本量小(26例),随访时间有限(平均2.6年),缺乏对照组。
- 为单中心回顾性研究,结论需更大样本和更长随访验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Pulmonary valve replacement is becoming the most frequent congenital heart surgery performed on adolescents and young adults. Numerous surgical options are available, including autologous pericardium, mechanical valves, allografts, and bioprosthetic valves. Each option has limitations with durability and freedom from reintervention for stenosis or insufficiency, particularly in the pediatric population. The purpose of this study was to analyze our uniquely designed, expanded polytetrafluoroethylene (ePTFE) valved conduit (VC) for right ventricular outflow tract reconstruction. METHODS: Beginning in 2012, ePTFE VC were implanted in 26 patients with a median age of 9.8 years (range, 1.0 to 15.9). Bicuspid VC were used in the first 3 patients, and tricuspid VC were used in 23 patients. The ePTFE VC is fashioned from commercially available ePTFE tube graft (16 mm in 1 patient, 20 mm in 7 patients, 24 mm in 18 patients) and 0.1 mm thick ePTFE membrane for the leaflet material. Valve function was assessed by echocardiogram after the implantation. RESULTS: There were no postoperative hospital deaths. Mean follow-up was 2.6 years (range, 4 months to 4.7 years), and there have been no reoperations for the ePTFE VC. There was one reintervention for stenosis at the distal anastomosis. Pulmonary insufficiency was mild or less in 24 patients (92%). The average peak instantaneous pressure gradient between the right ventricle and the pulmonary artery was 22.4 ± 15.1 mm Hg at latest follow-up. CONCLUSIONS: Compared with historical data for other pulmonary valve replacement options, our ePTFE VC shows superior medium-term performance, with less reintervention or significant valve dysfunction.
引用
- Ootaki Y, Welch AS, Walsh MJ, et al. Medium-Term Outcomes After Implantation of Expanded Polytetrafluoroethylene Valved Conduit. Ann Thorac Surg. 2017. PMID: 29100642. doi:10.1016/j.athoracsur.2017.07.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。