文献速递冠心病外科

基于内乳动脉的大隐静脉复合移植物的内皮剪切应力研究

Endothelial Shear Stress of the Saphenous Vein Composite Graft Based on the Internal Thoracic Artery.
PubMed 文献 · Ann Thorac Surg · 2017-11-23

研究比较冠状动脉旁路移植术(CABG)中内乳动脉(ITA)与大隐静脉(SV)复合移植物的术中及术后1年内皮剪切应力(ESS)。23例患者术中ESS差异显著,术后1年SV移植物ESS升高至与ITA无显著差异,初始ESS与移植物直径变化相关。

要点

  • 术中SV复合移植物ESS显著低于ITA,但术后1年升至与ITA相近水平。
  • 初始ESS与术后第一年移植物直径比例变化显著相关。
  • SV直径早期扩张后1年回缩,而ITA直径早期增加后保持稳定。

核心结论

  • 初始内皮剪切应力似乎与CABG术后第一年移植物直径的比例变化相关。
  • 术后1年SV复合移植物的ESS值与左ITA移植物相似。

研究设计与样本

  • 前瞻性观察性研究,纳入23例接受基于原位左ITA的SV Y型复合移植物的CABG患者。

主要发现

  • 术中近端ITA、远端ITA和SV直径分别为2.0±0.2 mm、1.8±0.3 mm和3.2±0.4 mm。
  • 术中ESS分别为41.0±21.0、28.4±25.2和4.3±3.0 dyne/cm²,三者间差异显著。
  • 早期造影近端和远端ITA直径显著增加后保持不变,SV直径早期增至3.7 mm(95%CI 3.5-4.0,p<0.001),1年降至2.9 mm(95%CI 2.7-3.2,p<0.001)。
  • 初始ESS与术后第一年移植物直径比例变化显著相关。
  • 1年造影时6例SV的ESS均升高,三种移植物ESS无显著差异(分别为29.9±7.9、28.8±7.9和21.6±16.3 dyne/cm²)。

临床怎么用

  • 术中ESS测量可能有助于预测SV复合移植物的术后重塑。
  • SV复合移植物在术后1年ESS可达到与ITA相近水平,支持其作为桥血管的远期适应性。

局限性

  • 样本量较小(23例术中,15例1年造影,6例Doppler导丝研究)。
  • 研究为观察性设计,无法确定ESS与重塑的因果关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Endothelial shear stress (ESS) has been suggested as a factor affecting atherosclerosis and remodeling of native vessels and bypass conduits. We compared ESS levels of internal thoracic artery (ITA) and saphenous vein (SV) composite grafts intraoperatively and 1 year after coronary artery bypass grafting (CABG). METHODS: Intraoperative ESS was calculated by measuring flow volumes and diameters of proximal and distal ITAs and SV conduits in 23 patients who received SV Y-composite grafts based on the in situ left ITA. Early (1.2 ± 0.5 days) and 1-year (12.9 ± 1.1 months) postoperative angiograms were performed in 23 and 15 patients, respectively. An intragraft Doppler-guidewire study for ESS measurement was performed in 6 patients during 1-year angiography. RESULTS: Intraoperative diameters of proximal and distal ITAs and SV conduits were 2.0 ± 0.2 mm, 1.8 ± 0.3 mm, and 3.2 ± 0.4 mm, respectively. ESS levels were significantly different between them (41.0 ± 21.0, 28.4 ± 25.2, and 4.3 ± 3.0 dyne/cm2, respectively). Proximal and distal ITA diameters increased significantly on early angiograms and remained unchanged, but SV diameter increased to 3.7 mm (95% confidence interval, 3.5 to 4.0 mm; p < 0.001) on the early angiogram and decreased to 2.9 mm (95% confidence interval, 2.7 to 3.2 mm; p < 0.001) at 1 year. Significant correlations were found between the initial ESS and proportional changes in conduit diameters during postoperative year 1. SV ESS increased in all 6 patients at 1 year, with no significant differences in ESS levels between the 3 conduits (29.9 ± 7.9, 28.8 ± 7.9, and 21.6 ± 16.3 dyne/cm2, respectively). CONCLUSIONS: Initial ESS appears to be associated with proportional changes in conduit diameters in the first year after CABG. ESS values of SV composite grafts were similar to left ITA conduits 1 year after CABG.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Hwang HY, Koo BK, Yeom SY, et al. Endothelial Shear Stress of the Saphenous Vein Composite Graft Based on the Internal Thoracic Artery. Ann Thorac Surg. 2017. PMID: 29174786. doi:10.1016/j.athoracsur.2017.08.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。