血液透析患者双侧与单侧胸廓内动脉桥血管的倾向性评分分析
本研究比较血液透析患者冠状动脉旁路移植术中双侧与单侧胸廓内动脉桥血管的结局。两组30天死亡率、深部胸骨伤口感染、卒中和呼吸衰竭无显著差异,中长期生存率亦无统计学差异。
要点
- 血液透析患者CABG使用双侧或单侧胸廓内动脉桥血管,围术期并发症和死亡率无显著差异。
- 匹配后两组1年、3年、5年生存率及无心脏死亡、无心脏事件生存率均无统计学差异。
- 对于移植血管有限的血液透析患者,双侧胸廓内动脉可能是多支血管重建的重要选择。
核心结论
- 血液透析患者CABG使用双侧胸廓内动脉桥血管在中长期结局上未显示优势,但围术期并发症或死亡无不良影响。
主要发现
- 双侧与单侧组30天死亡率分别为1.7%与0%(p=1.00),深部胸骨伤口感染5.1%与1.7%(p=0.62),卒中3.4%与3.4%(p=1.00),呼吸衰竭8.5%与11.9%(p=0.75)。
- Kaplan-Meier模型显示双侧与单侧组1年生存率分别为83.4%±5.1%与87.0%±4.6%,3年69.1%±7.3%与68.5%±6.9%,5年47.4%±10.45%与58.2%±8.1%。
- 两组生存率(p=0.81)、无心脏死亡生存率(p=0.51)和无心脏事件生存率(p=0.85)均无统计学差异。
临床怎么用
- 对于移植血管有限的血液透析患者,双侧胸廓内动脉可作为多支血管重建的重要选项。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Clinical evidence comparing the surgical risk and long-term effectiveness of the bilateral internal thoracic artery (BITA) and single internal thoracic artery (SITA) for coronary artery bypass grafting (CABG) in hemodialysis patients is limited. We sought to clarify the short-term and midterm outcomes of CABG using BITA or SITA grafts in hemodialysis patients. METHODS: Between October 2000 and December 2015, 161 hemodialysis patients underwent isolated CABG by internal thoracic artery grafting; 67 received BITA grafts and 94 SITA grafts. Propensity score matching was used to compare 59 BITA and SITA patient pairs. RESULTS: BITA and SITA grafts resulted in comparable 30-day mortality (1.7% vs 0%, p = 1.00), incidence of deep sternal wound infection (5.1% vs 1.7%, p = 0.62), stroke (3.4% vs 3.4%, p = 1.00), and respiratory failure (8.5% vs 11.9%, p = 0.75). The Kaplan-Meier model showed the survival rate in the BITA and SITA groups was 83.4% ± 5.1% vs 87.0% ± 4.6% at 1 year, 69.1% ± 7.3% vs 68.5% ± 6.9% at 3 years, and 47.4% ± 10.45% vs 58.2% ± 8.1% at 5 years of follow-up, respectively. There were no statistical differences in survival (p = 0.81), freedom from cardiac death (p = 0.51), or freedom from cardiac events (p = 0.85). CONCLUSIONS: CABG using BITA grafts showed no advantages in midterm outcome among hemodialysis patients; however, there were no adverse effects on perioperative morbidity or death. For hemodialysis patients with limited available conduits, BITA may be an important option for multivessel revascularization.
引用
- Nakahara Y, Yoshida S, Kanemura T, et al. Bilateral Internal Thoracic Artery Grafts in Hemodialysis: A Single-Center Propensity Score Analysis. Ann Thorac Surg. 2017. PMID: 28964409. doi:10.1016/j.athoracsur.2017.05.084
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。