文献速递心外重症与机械循环支持

HeartMate II 左心室辅助装置肋下换泵:体外与非体外循环比较

Improved Approach With Subcostal Exchange of the HeartMate II Left Ventricular Assist Device: Difference in On and Off Pump?
PubMed 文献 · Ann Thorac Surg · 2017-07-29

该回顾性研究纳入2009年5月至2016年7月间33例HeartMate II左心室辅助装置换泵患者,比较再次胸骨切开、肋下入路体外循环(ON-CPB SC)和肋下入路非体外循环(OFF-CPB SC)三种策略。结果显示肋下入路非体外循环组拔管时间和ICU住院时间显著缩短,胸骨切开组红细胞输注需求更高,而30天和90天生存率各组相当。

要点

  • 肋下入路换泵可避免再次胸骨切开,减少输血需求并加速康复。
  • 非体外循环肋下换泵的拔管时间和ICU住院时间显著短于胸骨切开和体外循环肋下组。
  • 三种入路的30天和90天生存率相当。

核心结论

  • 与胸骨切开相比,肋下入路换泵可显著改善恢复时间并降低输血需求。
  • 肋下入路在体外循环和非体外循环下均可安全实施。

研究设计与样本

  • 回顾性综述,纳入2009年5月至2016年3月(结果部分为2009年5月1日至2016年7月31日)接受HeartMate II左心室辅助装置换泵的患者。
  • 共33例换泵,分为再次胸骨切开组(11例)、肋下入路体外循环组(ON-CPB SC)和肋下入路非体外循环组(OFF-CPB SC,12例)。

主要发现

  • 各组年龄(p=0.75)、性别(p=0.95)和换泵指征(p=0.94)无显著差异。
  • 胸骨切开组红细胞输注需求更高(p<0.001)。
  • OFF-CPB SC组拔管时间中位数1天、ICU住院时间中位数2.5天,显著短于胸骨切开组(2.5天和21天)和ON-CPB SC组(1.5天和5天)。
  • 各组30天和90天生存率相当。

临床怎么用

  • 对于HeartMate II左心室辅助装置换泵,可优先考虑肋下入路以避免再次胸骨切开。
  • 肋下入路可根据情况选择体外循环或非体外循环下实施。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The HeartMate II (St. Jude Medical, Inc, St. Paul, MN [previously Thoratec]) left ventricular assist device (LVAD) exchange has traditionally involved a redo sternotomy. Alternate minimally invasive subcostal approaches have the advantage of avoiding sternal reentry, excessive bleeding, and prolonged recovery. METHODS: This retrospective review included patients who underwent an exchange from May 2009 to March 2016. The patients were divided into three cohorts: (1) redo sternotomy, (2) subcostal approach involving cardiopulmonary bypass (CPB) (ON-CPB SC), and (3) subcostal approach off the CPB pump (OFF-CPB SC). Data pertaining to patients' baseline characteristics and outcomes were collected and analyzed. RESULTS: From May 1, 2009 to July 31, 2016, 33 HeartMate II LVAD exchanges were performed. There were 11 redo sternotomies and 22 subcostal exchanges, 12 of which were in the OFF-CPB SC group. There was no significant difference among the groups in terms of age (p = 0.75), sex (p = 0.95), and indication for exchange (p = 0.94). There was a higher red blood cell transfusion requirement within the sternotomy cohort (p < 0.001). The median time to extubation and the intensive care unit length of stay were significantly shorter in the OFF-CPB SC group (1 and 2.5 days, respectively) than in the sternotomy (2.5 and 21 day, respectively) and ON-CPB SC groups (1.5 and 5 days, respectively). The 30-day and 90-day survival rates were equivalent among the cohorts. CONCLUSIONS: Exchange of the HeartMate II LVAD can be accomplished with significantly improved recovery time and transfusion requirement through a less invasive subcostal approach when compared with sternotomy. The subcostal approach can be performed safely both on and off cardiopulmonary bypass.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Gaffey AC, Chen CW, Chung JJ, et al. Improved Approach With Subcostal Exchange of the HeartMate II Left Ventricular Assist Device: Difference in On and Off Pump? Ann Thorac Surg. 2017. PMID: 28760470. doi:10.1016/j.athoracsur.2017.04.047

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。