文献速递瓣膜外科

经导管主动脉瓣置换术中脑灌注扰动监测研究

Intraoperative Cerebral Perfusion Disturbances During Transcatheter Aortic Valve Replacement.
PubMed 文献 · Ann Thorac Surg · 2017-08-16

本研究对31例全麻下经股动脉行经导管主动脉瓣置换术的患者进行脑氧饱和度监测,以评估术中低灌注事件。快速心室起搏期间常见显著脑去饱和与术后充血,但未发现这些术中扰动与客观神经损伤相关。

要点

  • 快速心室起搏可致脑氧饱和度显著下降,需警惕术中脑低灌注。
  • 术后磁共振成像定义的缺血性病灶常见,但无临床显性卒中。
  • 脑氧饱和度扰动与客观神经损伤之间未检测到关联。

核心结论

  • 脑氧饱和度对快速心室起搏反应迅速,显著去饱和与充血常见,但未检测到其与客观神经损伤的关联。

研究设计与样本

  • 前瞻性观察研究,31例全麻下经股动脉行经导管主动脉瓣置换术患者接受脑氧饱和度监测。
  • 系列神经、认知及脑磁共振成像评估用于客观量化围术期神经损伤。

主要发现

  • 快速心室起搏时脑氧饱和度相对基线下降>12%者12/31(68%),>20%者9/31(29%)。
  • 绝对测量值<50%者10/31(33%)。
  • 主动脉瓣狭窄解除后即刻充血超基线>10%者14/31(45%),>20%者5/31(16%)。
  • 术后认知功能障碍3/31(10%),新发磁共振成像定义缺血病灶17/28(61%)。
  • 无患者发生临床显性卒中。

临床怎么用

  • 术中脑氧饱和度可实时反映快速心室起搏相关的脑灌注变化,可用于监测但尚不能据此推断神经损伤风险。

局限性

  • 样本量小(31例),仅观察性设计,未检测到关联可能受样本量限制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Transcatheter aortic valve replacement entails profound and unavoidable hemodynamic perturbations that may contribute to the neurological injury associated with the procedure. METHODS: Thirty-one patients were monitored with cerebral oximetry as a surrogate marker of perfusion while undergoing transcatheter aortic valve replacement via a transfemoral approach under general anesthesia to detect intraoperative hypoperfusion insult. Serial neurologic, cognitive, and cerebral magnetic resonance imaging assessments were administered to objectively quantify perioperative neurologic injury and ascertain any association with significant cerebral oximetry disturbances. RESULTS: Cerebral oximetry reacted promptly to rapid ventricular pacing with significant cerebral desaturation, relative to baseline, of greater than 12% and greater than 20% in 12 of 31 (68%) and 9 of 31 (29%) patients, respectively; or to an absolute measurement of less than 50% in 10 of 31 (33%) patients. Hyperemia occurred immediately following relief of aortic stenosis exceeding baseline by greater than 10% and greater than 20% in 14 of 31 (45%) and 5 of 31 (16%) patients. Postoperative cognitive dysfunction was evident in 3 of 31 (10%) patients and new magnetic resonance imaging-defined ischemic lesions were seen in 17 of 28 (61%) patients. No patient experienced clinically apparent stroke. CONCLUSIONS: Cerebral oximetry reacted promptly to rapid ventricular pacing with significant desaturation and hyperemia a common occurrence. However, no association between this intraoperative insult and objective neurologic injury was detected.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Fanning JP, Walters DL, Wesley AJ, et al. Intraoperative Cerebral Perfusion Disturbances During Transcatheter Aortic Valve Replacement. Ann Thorac Surg. 2017. PMID: 28821337. doi:10.1016/j.athoracsur.2017.04.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。