冠脉搭桥术中减少脑栓塞事件的手术策略:分层前瞻性随机试验
该研究纳入142例低级别主动脉病变(epiaortic超声I/II级)行首次孤立CABG的患者,非体外循环组随机采用部分钳夹或免钳夹装置(CFD),体外循环组随机采用单钳夹或双钳夹策略,以经颅多普勒检测的高强度瞬态信号(HITS)总数为主要终点。非体外循环组CFD的HITS中位数高于部分钳夹组(30.0 vs 7.0,P<.0001);体外循环组单钳夹与双钳夹的HITS中位数无显著差异(10.0 vs 16.0,P=.10);各组神经认知结局无差异。
要点
- 非体外循环CABG中,CFD较部分钳夹增加脑栓塞事件。
- 体外循环CABG中,单钳夹未显著减少栓塞事件。
- 低级别主动脉病变患者神经认知结局组间无差异。
核心结论
- 低级别主动脉病变患者非体外循环CABG中,CFD与部分钳夹相比增加脑栓塞事件。
- 体外循环CABG中单钳夹策略未显著减少栓塞事件。
研究设计与样本
- 2012至2015年纳入142例低级别主动脉病变(epiaortic超声I/II级)行首次孤立CABG的患者。
- 非体外循环组随机分为部分钳夹(n=36)或CFD(n=36)。
- 体外循环组随机分为单钳夹(n=34)或双钳夹(n=36)。
- 术中以经颅多普勒超声检测大脑中动脉的高强度瞬态信号(HITS)。
- 基线和术后30天进行神经认知测试,主要终点为HITS总数。
主要发现
- 非体外循环组CFD亚组HITS中位数高于部分钳夹亚组(30.0,IQR 22-43 vs 7.0,IQR 0-16;P<.0001)。
- CFD亚组中,使用1个CFD患者的HITS中位数低于使用>1个CFD者(12.5,IQR 4-19 vs 36.0,IQR 25-47;P=.001)。
- 体外循环组单钳夹与双钳夹的HITS中位数分别为10.0(IQR 3-17)和16.0(IQR 4-49),P=.10。
- 各组神经认知结局无差异。
临床怎么用
- 对低级别主动脉病变行非体外循环CABG时,选择部分钳夹可能减少脑栓塞事件。
- 体外循环CABG中单钳夹策略在减少栓塞事件方面未显示显著优势。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To determine the impact of different aortic clamping strategies on the incidence of cerebral embolic events during coronary artery bypass grafting (CABG). METHODS: Between 2012 and 2015, 142 patients with low-grade aortic disease (epiaortic ultrasound grade I/II) undergoing primary isolated CABG were studied. Those undergoing off-pump CABG were randomized to a partial clamp (n = 36) or clampless facilitating device (CFD; n = 36) strategy. Those undergoing on-pump CABG were randomized to a single-clamp (n = 34) or double-clamp (n = 36) strategy. Transcranial Doppler ultrasonography (TCD) was performed to identify high-intensity transient signals (HITS) in the middle cerebral arteries during periods of aortic manipulation. Neurocognitive testing was performed at baseline and 30-days postoperatively. The primary endpoint was total number of HITS detected by TCD. Groups were compared using the Mann-Whitney U test. RESULTS: In the off-pump group, the median number of total HITS were higher in the CFD subgroup (30.0; interquartile range [IQR], 22-43) compared with the partial clamp subgroup (7.0; IQR, 0-16; P < .0001). In the CFD subgroup, the median number of total HITS was significantly lower for patients with 1 CFD compared with patients with >1 CFD (12.5 [IQR, 4-19] vs 36.0 [IQR, 25-47]; P = .001). In the on-pump group, the median number of total HITS was 10.0 (IQR, 3-17) in the single-clamp group, compared with 16.0 (IQR, 4-49) in the double-clamp group (P = .10). There were no differences in neurocognitive outcomes across the groups. CONCLUSIONS: For patients with low-grade aortic disease, the use of CFDs was associated with an increased rate of cerebral embolic events compared with partial clamping during off-pump CABG. A single-clamp strategy during on-pump CABG did not significantly reduce embolic events compared with a double-clamp strategy.
引用
- Halkos ME, Anderson A, Binongo JNG, et al. Operative strategies to reduce cerebral embolic events during on- and off-pump coronary artery bypass surgery: A stratified, prospective randomized trial. J Thorac Cardiovasc Surg. 2017. PMID: 28728785. doi:10.1016/j.jtcvs.2017.04.089
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。