文献速递肺外科

超声能量在开放肺叶切除中封闭肺动脉的I期临床试验

Pulmonary artery sealing with ultrasonic energy in open lobectomy: A phase I clinical trial.
PubMed 文献 · J Thorac Cardiovasc Surg · 2017-02-09

该I期临床试验前瞻性纳入拟行择期开放肺叶切除的患者,评估超声能量血管封闭装置封闭肺动脉的安全性。结论认为直径≤7 mm的肺动脉分支在开放肺叶切除中可安全使用超声能量封闭。

要点

  • 直径≤7 mm的肺动脉分支在开放肺叶切除中可用超声能量装置安全封闭。
  • 10例分析患者中14支肺动脉被封闭,平均直径5 mm(范围2-7 mm)。
  • 无与超声肺动脉封闭相关的术中或术后出血,无术后死亡。

核心结论

  • 开放肺叶切除中,直径≤7 mm的肺动脉分支使用超声能量血管封闭装置可安全封闭。

研究设计与样本

  • I期临床试验,前瞻性纳入拟行择期开放(开胸)肺叶切除的患者,目标样本量10例。
  • 术中测量肺动脉直径,所有≤7 mm的分支用超声能量血管封闭装置离断,其余肺叶切除按标准方式进行。
  • 严格记录术中及术后出血。

主要发现

  • 纳入分析的10例患者中,共14支肺动脉被超声装置封闭,平均血管直径5 mm(范围2-7 mm)。
  • 1例因支气管动脉出血(非该装置封闭的血管)再次手术。
  • 无与超声肺动脉封闭相关的术中或术后出血,无术后死亡。

临床怎么用

  • 在开放肺叶切除中,对直径≤7 mm的肺动脉分支可考虑使用超声能量血管封闭装置进行封闭。
  • 该装置在电视辅助胸腔镜肺叶切除中可能使小而短的肺动脉分支封闭比血管内镜缝合器更安全,但需进一步研究后方可广泛应用。

局限性

  • 为I期临床试验,目标样本量10例,实际分析仅10例,样本量小。
  • 研究仅在开放肺叶切除中评估,电视辅助胸腔镜肺叶切除中的应用尚需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Pulmonary artery branch sealing in video-assisted thoracoscopic surgical lobectomy is usually achieved with vascular endostaplers. Iatrogenic pulmonary artery injury may be caused by endostaplers. We evaluated the safety of pulmonary artery sealing with an ultrasonic energy vessel-sealing device in a phase I clinical trial evaluating in vivo safety of the device during open lobectomy. METHODS: Patients scheduled to undergo elective open (thoracotomy) pulmonary lobectomy were prospectively enrolled. Target sample size was 10 patients. Pulmonary artery diameter was measured intraoperatively. All branches ≤7 mm were divided with an ultrasonic energy vessel-sealing device. The remainder of the lobectomy was performed in a standard fashion. Intraoperative and postoperative bleeding were strictly recorded. RESULTS: Eighteen patients were prospectively enrolled. Eight patients were not amenable to pulmonary artery sealing with the device. In the 10 patients included in the analysis, a total of 14 pulmonary arteries were sealed with the ultrasonic device. The mean vessel diameter was 5 mm (range, 2-7 mm). One patient underwent reoperation for bronchial artery bleeding (vessel not sealed with device). There was no intra- or postoperative bleeding related to ultrasonic pulmonary artery sealing. There was no postoperative mortality. CONCLUSIONS: Pulmonary artery sealing for vessels with diameter ≤7 mm was safely achieved with an ultrasonic energy vessel-sealing device in open lobectomy. The use of ultrasonic energy vessel-sealing devices in video-assisted thoracoscopic surgical lobectomy may have the advantage of making small, short, pulmonary artery branch sealing safer than with vascular endostaplers. Further studies are necessary before widespread application in lobectomy, including video-assisted thoracoscopic surgical lobectomy.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Goudie E, Thiffault V, Jouquan A, et al. Pulmonary artery sealing with ultrasonic energy in open lobectomy: A phase I clinical trial. J Thorac Cardiovasc Surg. 2017. PMID: 28526110. doi:10.1016/j.jtcvs.2016.12.049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。